Page 52 of 66
Data administration
553-2811-200
Standard 6.0
December 1994
Prompt
Response
Comments
1
Gather data to add, change, or remove a CPI Digital Trunk Loop. Response to the
following prompts in
LD 17
is required. Defaults are in parentheses.
REQ
NEW, OUT,
CHG, END
Add data, remove data, change data, or end LD 17.
TYPE
CFN
Configuration data block.
CEQU
Yes
Change CE parameters.
DLOP
lll dd ff
Digital Trunk loop options.
lll = network loop number 0-159.
dd = number of data calls 0-(24).
ff = frame format D2, D3, D4, or ESF.
The default for frame format (ff) is ESF if prompt MODE is set to
PRI; D3 if MODE is set to DTI or LINK.
DTIC
0-159
The starting network loop slot occupied by the DTI card. It marks,
as occupied, the loop slots taken up by the DTI card. On
non-network loops, enter <cr> and ignore the message SCH
2035.
OVLY
Yes
Change overlay area options.
SID
xxxx
System ID number.
The SID is used for polling a Meridian 1 for ACD, CDR, and Traffic
reports.
DROL
60
Include DTI Hardware diagnostic in daily routines.