Page 14 of 66
DTI installation
553-2811-200
Standard 6.0
December 1994
7
Attach cables. Refer to
“Cable requirements” on page 10
for general
cable information.
cable connections. Illustrations of the cabling arrangement for specific
systems appear in the figures in each section.
Note:
The figures in each section show cabling arrangements for the
QPC720 card. The equivalent connections on the DTI card are as
follows:
8
If required, install connecting blocks at MDF or wall mounted
cross-connect terminal.
9
If required, designate connecting blocks at MDF or wall mounted
cross-connect terminal.
10
If required, install Network Channel Terminating Equipment (NCTE).
11
Cross-connect DTI circuits.
12
Run DTI acceptance/verification tests.
13
Add related office data into system memory. Refer to the work order and
“Data administration” on page 43
.
QPC720 J4 = QPC472 J5