Page 12 of 66
DTI installation
553-2811-200
Standard 6.0
December 1994
shows the cable connections for the different systems. Not all cables
apply to every system; read the Comments section carefully.
Table 8
Cable connections to the Clock Controller, Network, Patch panel, I/O panel, and Echo
Canceller (Part 1 of 2)
Cable
type
From
CON
To
DES
CON
Comments
QCAD130
NT8D79xx
QPC720/
QPC472
J1
J1
QPC471
QPC775
CC-0
J2
Run only when DTI is
primary reference clock
source
QCAD130
NT8D79xx
QPC720/
QPC472
J1
QPC471
CC-0
J1
Run only when DTI is
secondary reference clock
source.
QCAD130
NT8D79xx
QPC720
J2
QPC471
CC-1
J2
Only when primary clock
source. For RT in
Single-Group mode only;
not for ST, STE, or MS.
QCAD130
NT8D79xx
QPC720
J2
QPC471
CC-1
J1
Only when secondary
clock source. For N/NT/RT
in Single-Group mode only;
not for ST, STE, or MS.
QCAD110
NT8D74xx
QPC471
QPC775
J3
QPC417
SCG0
SCG1
Applies only to XN/XT
QCAD125
NT8D75xx
QPC471
J3
QPC471
CC-1
J3
Applies only to N/NT/RT
Single-Group mode.
QCAD124
NT8D85xx
QPC720/
QPC472
J3
Network
Run to connector on
associated Network card.
(For Half-Group mode only
for the MS; for
Single-Group mode only
for the N/NT/RT).
QCAD124
NT8D85xx
QPC720/
QPC472
J3
Network
Run to connector on
associated Network card.
Applies only to N/NT/RT
Half-Group mode.