MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide
29
Copyright © 2006 Nortel Networks
Figure 6 Sun Fire V100 server cabling to layer-2 switch
Note 1:
Net 0 and Net 1 are for redundancy. It is preferable
that each Ethernet port get cabled to a different layer-2 switch,
if available, for maximum redundancy.
Note 2:
The two Ethernet switches are physically linked
together through either cascade modules or Ethernet links.
2
Plug in the power cords at the back of the V100 server.
Connecting the Sun Fire V100 server to the MRV LX terminal server
The MCS 5100 platform uses the Sun Fire V100 server medium
configuration.
Note:
This server is only available in an AC power configuration.
Procedure 3 Connecting the serial port on the V100 to the MRV LX
terminal server
At the back of the Sun Fire V100 server,
1
Connect the Sun Fire V100 server A/LOM serial port and B-
serial port to the MRV LX terminal server:
ATTENTION
Do
not
power up the server at this time.
Summary of Contents for NN10364-301
Page 2: ......
Page 6: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 6 Copyright 2006 Nortel Networks...
Page 8: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 8 Copyright 2006 Nortel Networks...
Page 16: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 16 Copyright 2006 Nortel Networks...
Page 22: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 22 Copyright 2006 Nortel Networks...
Page 32: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 32 Copyright 2006 Nortel Networks...
Page 44: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 44 Copyright 2006 Nortel Networks...
Page 64: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 64 Copyright 2006 Nortel Networks...
Page 66: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 66 Copyright 2006 Nortel Networks...
Page 68: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 68 Copyright 2006 Nortel Networks...
Page 78: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 78 Copyright 2006 Nortel Networks...
Page 94: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 94 Copyright 2006 Nortel Networks...
Page 100: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 100 Copyright 2006 Nortel Networks...
Page 106: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 106 Copyright 2006 Nortel Networks...
Page 118: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 118 Copyright 2006 Nortel Networks...
Page 124: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 124 Copyright 2006 Nortel Networks...
Page 126: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 126 Copyright 2006 Nortel Networks...
Page 132: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 132 Copyright 2006 Nortel Networks...
Page 138: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 138 Copyright 2006 Nortel Networks...
Page 146: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 146 Copyright 2006 Nortel Networks...
Page 160: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 160 Copyright 2006 Nortel Networks...
Page 166: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 166 Copyright 2006 Nortel Networks...
Page 168: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 168 Copyright 2006 Nortel Networks...
Page 174: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 174 Copyright 2006 Nortel Networks...
Page 175: ......