
MCS 2-server Sun Fire V100 Solaris Installation and Commissioning Guide
111
Copyright © 2006 Nortel Networks
The shaded rows indicate values that must be addressed by the
installer.
6
Use the values from the table that follows to complete the SIP
TCF Base tab parameters.
7
Use the values from the following table to complete the In
Memory Database tab parameters.
The shaded rows indicate values that must be addressed by the
installer.
Table 6 Database Base tab
Parameter
Recommended value
Notes
Example
Primary Host
<machine logical IP of
database server>
192.168.14.111
120.120.13.22
Connections
8
default
Secondary Host
Not applicable
Table 7 SIP TCF Base tab
Parameter
Recommended value
Notes
Example
Transport Config
UDP=192.168.14.31:506
0:optional:name=sipLsc
Conduit;TCP=192.168.1
4.31:5060:optional:name
=sipLscConduit
This is
the IP
address
of the
App svr
120.120.13.25
Invite Timer
128000
default
Maximum Number of
Redirections
5
default
Initial Maximum Hop Value
20
default
Table 8 In Memory Database tab (Sheet 1 of 2)
Parameter
Recommended
value
Notes
Example
Number of domains
500
default
Update interval for domain
information
600
default
Summary of Contents for NN10364-301
Page 2: ......
Page 6: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 6 Copyright 2006 Nortel Networks...
Page 8: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 8 Copyright 2006 Nortel Networks...
Page 16: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 16 Copyright 2006 Nortel Networks...
Page 22: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 22 Copyright 2006 Nortel Networks...
Page 32: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 32 Copyright 2006 Nortel Networks...
Page 44: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 44 Copyright 2006 Nortel Networks...
Page 64: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 64 Copyright 2006 Nortel Networks...
Page 66: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 66 Copyright 2006 Nortel Networks...
Page 68: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 68 Copyright 2006 Nortel Networks...
Page 78: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 78 Copyright 2006 Nortel Networks...
Page 94: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 94 Copyright 2006 Nortel Networks...
Page 100: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 100 Copyright 2006 Nortel Networks...
Page 106: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 106 Copyright 2006 Nortel Networks...
Page 118: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 118 Copyright 2006 Nortel Networks...
Page 124: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 124 Copyright 2006 Nortel Networks...
Page 126: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 126 Copyright 2006 Nortel Networks...
Page 132: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 132 Copyright 2006 Nortel Networks...
Page 138: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 138 Copyright 2006 Nortel Networks...
Page 146: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 146 Copyright 2006 Nortel Networks...
Page 160: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 160 Copyright 2006 Nortel Networks...
Page 166: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 166 Copyright 2006 Nortel Networks...
Page 168: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 168 Copyright 2006 Nortel Networks...
Page 174: ...NN10364 301 MCS 5100 3 5 Standard 6 0 December 2006 174 Copyright 2006 Nortel Networks...
Page 175: ......