Working with ISDN /
79
N0130943 02
Modular ICS 7.1 Installer Guide
4. Disable each card in
Maintenance
under
Module
Status
.
5. Under
Hardware
, select a card type:
BRI-ST
,
BRI-U2
,
BRI-U4
.
6. Under
Hardware
, select the type for each loop:
• for a BRI card, select
T
or
S
if the card type is BRI-ST
• for a BRI-U2 or BRI-U4 card, select
LT
or
NT
7. If the card uses a T or NT loop, enter the following
information, as supplied by your service provider:
• the SPID assigned to the loop
• the number of B-channels associated with each SPID
• the Network DNs used with the network SPID
• the call type of the Network DN
Repeat the programming for the second network SPID, if
any.
If the T or NT loop is used for D-packet service:
• turn on the service
• assign the appropriate S-loop mapping for BRI-ST
cards or LT-loop mapping for BRI-U2 or U4 cards
• assign the TEIs to the loop. These are provided by the
telco to support a point-of-sale terminal adapter or
other D-packet service device.
If the loop type is S, select the sampling used on the loop.
If the loop type is S or LT:
• assign ISDN DNs to the loop
• designate one of the assigned ISDN DNs to be the DN
for the loop (Loop DN).
Note:
You can have a maximum of 30 ISDN DNs on your
system. The default ISDN DN range is 667-696 on
Summary of Contents for Modular ICS 7.1
Page 2: ......
Page 46: ...46 How to use this document Modular ICS 7 1 Installer Guide N0130943 02...
Page 72: ...72 Welcome to ISDN Modular ICS 7 1 Installer Guide N0130943 02...
Page 102: ...102 Remote system access Modular ICS 7 1 Installer Guide N0130943 02...
Page 108: ...108 Controlling system access Modular ICS 7 1 Installer Guide N0130943 02...
Page 192: ...192 ETSI MCDN and Network features Modular ICS 7 1 Installer Guide N0130943 02...
Page 290: ...290 Modular ICS 7 1 Installer Guide N0130943 02...
Page 582: ...582 Link Status Modular ICS 7 1 Installer Guide N0130943 02...
Page 586: ...586 Usage Metrics Modular ICS 7 1 Installer Guide N0130943 02...