Carrier Remote IPE product description
Table 7
LCI and RCI power requirements (cont’d.)
Voltage source in VDC
LCI card
RCI card
–15V
70 mA
50 mA
+12V
70 mA
50 mA
–12V
70 mA
50 mA
Total Power
23.8 W
21.2 W
Carrier cable requirements
A link can include up to three carriers. In a Carrier Remote IPE column,
the carrier link terminates into the I/O panel connectors at the rear of the
IPE module. In a Carrier Remote IPE cabinet, the carrier link terminates
into the I/O panel connectors mounted on a bracket at the lower left-hand
side at the front of the Carrier Remote IPE cabinet.
The Carrier Remote IPE UEM column and the Carrier Remote IPE cabinet
support T1 or E1 carrier links. These carrier links are terminated as
follows:
•
T1/E1 carrier links use twisted-pair wires (120-ohm impedance) and
terminate into 8-pin modular jacks.
•
E1 carrier links may in some cases use coaxial cables (75 ohm
impedance) and terminate into BNC connectors, requiring an RJ-48 to
BNC adapters (supplied with the equipment) to connect the link to the
Carrier Panel assembly at the UEM I/O panel.
Carrier equipment planning form
Table 8 "Planning form" (page 48)
displays a planning form to use when
ordering carrier equipment. Enter the part number and the quantity for
each item required at the local and the remote site.
Table 8
Planning form
Select one carrier type: T1 or E1 (circle the selected carrier type and
enter only items required for that carrier type). Refer to
"Local site carrier hardware list" (page 13)
IPE wall-mounted cabinet hardware list" (page 16)
starting on
2 "Local site carrier hardware list" (page 13)
.
Item
Part
Number
Quantity at
local site
Quantity at
Remote IPE
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010