Carrier Remote IPE maintenance
11:00
1
1
1
1
1
1
10:00
0
0
0
0
0
0
Note: This report lists the 24-hour performance history for this
carrier. Ideally all the parameters should show 0 for optimum
performance. However, if the carrier is not in alarm state, it
can continue to perform within the specified threshold limits.
--End--
Disabling a carrier when idle
Follow the steps in
Procedure 44 “Disabling a carrier when idle to check
the carrier sparing function or to perform off-line carrier tests” (page
178)
to disable a carrier when idle to check the carrier sparing function
or to perform off-line carrier tests.
Procedure 44
Disabling a carrier when idle to check the carrier sparing function or to
perform off-line carrier tests
Step
Action
1
Execute the
S C
command to disable the desired primary carrier.
This command allows the calls in progress to complete before
the carrier can be disabled. The MMI terminal displays the
following screen to enable a change in carrier status:
To disable carrier 1 (set Equipped carrier 1 parameter
to N):
CRI::> S C
To set carrier parameters
Equipped carrier 0 (Yes or No) Y
Enable carrier 0. Enter Y to
enable or N to disable.
Equipped carrier 1 (Yes or No) N
Disable carrier 1.
Equipped carrier 2 (Yes or No) Y
To enable carrier 2
Enable #2 for Spare (Yes or No) Y
Defines carrier 2 as spare
Enable self clearing Alarms (Yes or
No) N
To enable/disable alarm
clearing
2
Track the number of calls still active on carrier 1 by executing
the
STAT
command:
LD 32
NPR000
STAT sl
Nortel Communication Server 1000
Carrier Remote IPE Fundamentals
NN43021-555 04.01
4 June 2010