Chapter 4 Installing option cards and DIMMs
NN46110-318 02.01
a
Set the VPN Router 2750 on the rack-mount shelf in the rack.
b
Insert one of the panhead screws through the bottom hole on each side of
the shelf into the hole in the rack, and tighten the screws (
Figure 4 on
page 31
).
12
Replace the front bezel
(Figure 25)
.
a
Hold the bezel by the two handles, and push the bezel onto the chassis.
b
Use a screwdriver, to tighten the two screws that secure the bezel to the
chassis.
Figure 25
Replacing the front bezel
Installing and replacing DIMMs
The VPN Router 2750 has two slots for dual inline memory modules (DIMM)
(
Figure 22 on page 66
). Unless you ordered additional memory, the VPN Router
2750 is shipped with one 256 MB DIMM installed. You can upgrade memory in
the gateway by installing a second 256 MB DIMM.