5
At the beginning of the defrost cycle, both the outdoor
condenser fan and compressor will turn off. After
approximately 30 seconds, the compressor will turn on
and begin to heat the outdoor coil causing the ice and
snow to melt.
NOTE:
While the ice and snow is melting, some steam
may rise from the outdoor unit as the warm coil causes the
melting frost to evaporate. When defrost is completed, the
outdoor fan motor will start, and the compressor will turn
off again. In approximately 30 seconds the compressor
will start up again and continue normal operation.
Operating the Heat Pump for Automatic Cooling
and Heating
1. Set the thermostat system switch to AUTO and the
thermostat fan switch to AUTO. See Figure 1.
NOTE:
Thermostat styles vary. Some models will not
include the AUTO mode and others will have the AUTO
in place of the HEAT and COOL. Others may include
all three. Refer to the instructions supplied with your
thermostat for specific instructions.
2. Set the thermostat temperature to the desired heating
and cooling temperature level(s). The outdoor unit and
the indoor blower will then cycle on and off in either
the heating or cooling mode of operation as required
to automatically maintain the indoor temperature within
the desired limits.
Operating the Indoor Blower Continuously
The continuous indoor blower operation is typically used to
circulate the indoor air to equalize a temperature unbalance
due to a sun load, cooking, or fireplace operation.
Set the thermostat fan mode to ON (Figure 1). The indoor
blower starts immediately, and will run continually until the
fan mode is reset to AUTO.
The continuous indoor blower operation can be obtained
with the thermostat system mode set in any position,
including OFF.
Shutting the Heat Pump Off
Change the thermostat’s system mode to OFF and the fan
mode to AUTO. See Figure 1.
NOTE:
The system will not
operate, regardless of the temperature selector setting.
HEAT PUMP MAINTENANCE
CAUTION:
Shut off all electrical power to the unit before
performing any maintenance on the system.
Failure to comply may result in personal injury
or death.
Proper maintenance is most important to achieve the best
performance from the appliance and should be performed
by a qualified service technician at least once a year.
Follow the maintenance schedule and the instructions
below for years of safe, trouble free operation.
Regular Cleaning
WARNING:
Do not place combustible material on or against
the unit cabinet. Do not place combustible
materials, including gasoline and any other
flammable vapors and liquids, in the vicinity of
the unit.
•
Clean or replace the indoor air filter at the start of each
heating and cooling season, and when an accumulation
of dust and dirt is visible on the air filter.
• Remove any leaves and grass clippings from the coil
in the outdoor unit, being careful not to damage the
aluminum fins.
• Check for obstructions, such as twigs, sticks, etc.
TROUBLESHOOTING
If the unit fails to operate, check the following:
•
The thermostat is properly set. See Cooling Operation
for air conditioning or Heating Operation for furnace or
air handler.
•
The unit disconnect fuses are in good condition and the
electrical power to the unit is turned on.
WARRANTY INFORMATION
A warranty certificate with full details is included with the
heat pump. Carefully review these responsibilities with
your dealer or service company. The manufacturer will not
be responsible for any costs found necessary to correct
problems due to improper setup, improper installation,
adjustments, improper operating procedure on the part
of the user, etc. Some specific examples of service calls
which are not included in the limited warranty are:
•
Correcting wiring problems in the electrical circuit
supplying the heat pump.
•
Resetting circuit breakers or other switches.
•
Adjusting or calibrating of thermostat.
USER INFORMATION