40
Primary Display
Secondary Display
Function Description
Reference Page(s)
Function
Function Name
Step 1
Step 2
Step 3
Default
6:QC
Quick
Connection Setiing
oFF
Default
The Quick Connect Multi System allows the installation of two units together
utilizing only the Quick Connect Cord.
• Quick Connect Multi System cannot allows more than 2 units. • All units within Quick Connect Multi System must be of the same model. • Dif
ferent models cannot work as Quick Connect Multi System.
• T
o activate the setting
7:CV
(Common V
ent),
6:QC
mode s
etting must be
'on'.
Installation Manual Page 44
on
7:CV
Common
Vent Setting
on
Default
W
he
n
No
rit
z
wa
te
r h
eat
er
s
ar
e
inst
alle
d
in
a
No
rit
z
Qu
ick
Con
ne
ct
Mu
lti
System, you can install a common venting system.
(This setting is available
only if '6:QC' mode is active.)
•
Do not use common venting if the water heater is used within a
Noritz Quick
Connect Mul
ti Sy
stem with other manufac
turer
’s water heaters
or other
models.
Installation Manual Page 45
oFF
8:FH
Fan
High RPM Compensation
Setting
(ex) 30
- 30 ~ 30
Factory Setting
Maximum Fan RPM : -30 ~ +30 PWM
9:FL
Fan
Low RPM Compensation
Setting
(ex) -30
- 30 ~ 30
Factory Setting
Minimum Fan RPM : -30 ~ +30 PWM
10:AG
AG
M Compensation Setting
(ex) -50
-50 ~ 50
Factory Setting
AGM Compensation : -50 ~ +50 Step
Installer Mode
Chapter
5.
–
Setting