37
Setting the Control Panel
Chapter 4. – Installation
Setting the Control Panel (High Elevation)
To set the High Elevation
1. Turn off the power to the control panel. Press and hold the
‘Function Button’ for approximately 5 seconds to get into the
‘Installer Mode’.
2. In ‘Installer Mode,’ turn the ‘Dial Button’ clockwise until the
display reads [5:EL].
3. ‘0-2’ will flash when the ‘Dial Button’ is pressed. (The default
setting is ‘0-2’ for installations at 0-1,999 ft elevation)
4. Turn the ‘Dial Button’ clockwise to select the value that
corresponds to the installation elevation.
5. Press the ‘Dial Button’ to store the current setting and return
back to ‘Installer Mode’.
Elevation above Sea Level
5:EL setting
0 ~ 1,999 ft (0 ~ 609 m)
0 - 2 (Default)
2,000 ~ 4,999 ft (610 ~ 1,523 m)
2 - 5
5,000 ~ 7,999 ft (1,524 ~ 2,438 m)
5 - 8
8,000 ~ 10,000 ft (2,439 ~ 3,048 m)
8 - 10