39
Primary Display
Secondary Display
Function Description
Reference Page(s)
Function
Function Name
Step 1
Step 2
Step 3
Default
3
:RT
Recirculation
Temperature
Setting
Lo
Select the level at which the water heater turns on or of
f according to the Re
-
circulation hot water temperature
.
(This setting is available only if '1:RC' mode
is active.)
• Choose a recirculation temperature setting from the following three options.
Lo
Burner OFF : (Set T
emperature)
+5°F(+3°C)
Burner ON : (Set
Temperature) -9°F(-5°C)
HI-1
Burner OFF : (Set T
emperature)
+9°F(+5°C)
Burner ON : (Set
Temperature) -3°F(-2°C)
HI-2
Burner OFF : (Set T
emperature)
+13°F(+7°C)
Burner ON : (Set
Temperature)
HI-1
Default
HI-2
4:HT
Hot W
ater
Temperature Setting
Lo
Select the level at which the water heater turns on or of
f according to the
domestic hot water temperature.
• Choose a hot water temperature setti
ng from the following three options
.
Lo
Burner OFF :
(Set T
emperature)
+9°F(+5°C)
Burner ON :
(Set T
emperature)
HI-1
Burner OFF :
(Set T
emperature)
+18°F(+10°C)
Burner ON :
(Set
Temperature) + 9°F(+5°C)
HI-2
Burner OFF :
(Set T
emperature)
+27°F(+15°C)
Burner ON :
(Set T
emperature)
+18°F(+10°C)
HI-1
Default
HI-2
5:EL
El
evation
0-2
Default
Select an elevation
range from the following four options based on where the
W
ater Heater is installed.
Installation
Manual Page 37
2-5
5-8
8-10
Installer Mode
Chapter
5.
–
Setting
7:EL
setting
Elevation above Sea Level
0 - 2
0~1,999ft (0~609m)
2 - 5
2,000~4,999ft (610~1,523m)
5 - 8
5,000~7,999ft (1,524~2,438m)
8 - 10
8,000~10,000ft (2,439~3,048m)
Summary of Contents for NRCP111-DV