background image

15

3 AMP

FUSE

COMPRESSOR

OUTDOOR

F

AN MO

T

O

R

BLO

WER

M

OTO

R

DU

AL

CAP

A

CIT

OR

S

R

C

L2

L1

T2

T1

COMPRESSOR

CONT

A

C

T

O

R

24V

COM

HIGH PRESSURE

SWITCH

240V

LO

PRESSURE

SWITCH

(SELECT

MODELS

ONL

Y)

S

R

C

N

G

L

C

5

4

3

2

1

9

8

7

6

5

4

3

2

1

9

8

7

6

COM

NO

NC

THERMOST

A

T

THERMOST

A

T

F

H

C

LO

AD RELA

Y

TRANSFORMER

BLUE

ORANGE

RED

BLA

CK

BLA

CK

YELLO

W

THERMOST

A

T

YELLO

W

YELLO

W/BLA

CK

YELLO

W

YELLO

W/BLA

CK

YELLO

W

1.

 Couper le courant a

v

ant de faire letretien.

2.

 Emplo

y

ez uniquement des conducteur

s en cuivre

.

3.

 Ne con

vient pas aux installations de plus de 150 

V a la terre

.

FIELD WIRING

LEGEND:

LO

W V

O

LT

A

G

E

HIGH V

O

LT

A

G

E

P

a

c

k

a

g

ed Air Conditioner - Single Phase

NO

TES:

1.

 Disconnect all po

wer bef

ore ser

vicing.

2.

 For suppl

y

 connections use copper conductor

s onl

y

.

3.

 Not suitab

le on systems that e

x

ceed 150 

V to gr

ound.

4.

 For replacement wires use conductor

s suitab

le f

or 105° C.

5.

 See installation instructions f

o

r b

lo

w

er motor airflo

w settings

YELLO

W

RED

GREEN

BR

O

W

N

ORANGE

RED

RED

RED

RED

RED

BLA

CK

BLA

CK

BLACK

WHITE

WHITE

WHITE

WHITE

ORANGE

GREEN/YELLO

W

GREY

BLUE

YELLOW

RED

Figure 12. Wiring Diagram

WD # 7108060

Summary of Contents for 13 SEER Single Package Air Conditioner

Page 1: ...our problem call your installing contractor or distributor in your area INTRODUCTION Mostanyairconditionerwillkeepyoucool Ourairconditionerwasdesignedtodo it efficiently Efficiency means less cost to...

Page 2: ...2...

Page 3: ...rmostat at the comfort level you wish and then leave it alone Let it control the operation of the air conditioning system If you get chilly turn it up a degree at a time until comfort is restored 3 It...

Page 4: ...al supply should be checked to de termine if adequate power is available If there is any question concerning the power supply contact the local power company Inspecting Equipment All units are securel...

Page 5: ...ervicing and air circulation Do NOT install unit in a confined or recessed areathatwillallowdischargeairfromtheunit to re circulate into the condenser air inlet through the coil Service Access Clearan...

Page 6: ...how the floor joist location willaffectcuttingtheopeningneededforthebox Floor joists generally are located on 16 centers leaving 14 3 8 between joists After measuring the return air box approximately...

Page 7: ...performance of an air conditioning system than any other factor The duct must be sufficientlylargetoconductanadequateamount of air to each register Air ducts should be installed in accordance with the...

Page 8: ...to the corresponding fittings with the clamps pro vided with the ducts Note All connections should be leak tight or a loss in cooling capacity will result c Theflexibleductsmaybecuttotherequired leng...

Page 9: ...low wires from the unit to the R and Y terminals respectively on thethermostatsubbase Connectthegreen wire to the yellow wire at the unit See the instructionsheetpackedwiththethermostat for detailed m...

Page 10: ...nctions correctly h Dial the thermostat higher than room tem perature The unit should stop i If using a combination heating cooling ther mostat set to the HEAT position Proceed to check for correct fu...

Page 11: ...142 331 140 144 278 147 296 147 313 147 333 144 353 142 146 299 151 317 150 335 148 355 146 375 144 148 321 153 339 152 357 150 377 148 397 147 150 324 157 342 156 360 154 379 152 399 150 152 346 160...

Page 12: ...0 417 169 440 167 149 379 175 400 174 421 173 442 171 151 403 178 424 177 445 175 153 427 181 448 180 155 452 184 157 3 5 OUTDOOR TEMPERATURE F TON 70 75 80 85 90 95 100 105 Suct Press Liq Press Dis T...

Page 13: ...76 433 176 455 176 149 394 180 415 180 436 181 457 180 151 418 185 439 185 461 185 153 443 189 464 189 155 467 194 157 5 OUTDOOR TEMPERATURE F TON 70 75 80 85 90 95 100 105 Suct Press Liq Press Dis Te...

Page 14: ...er le courant avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE Pack...

Page 15: ...ployez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE Packaged Air Conditioner Single Phase NOTES 1 D...

Page 16: ...ations and illustrations subject to change without notice and without incurring obligations Printed in U S A 06 08 708901 7089010 INSTALLER PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOW...

Reviews: