13 SEER - Charging Charts - Continued

3

OUTDOOR TEMPERATURE  (°F)

TON

70

75

80

85

90

95

100

105

Suct. 

Press.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

131 267 145

133 269 151 291 148

135 271 156 294 153 316 150

137 276 156 296 158 318 155 340 153

139 280 159 300 159 320 160 342 157 365 155

141

304 162 324 162 344 162 367 160 389 158

143

328 166 348 165 369 164 391 162 413 161

145

352 169 372 168 393 166 415 165 438 163

147

355 172 376 172 397 170 417 169 440 167

149

379 175 400 174 421 173 442 171

151

403 178 424 177 445 175

153

427 181 448 180

155

452 184

157

3.5

OUTDOOR TEMPERATURE  (°F)

TON

70

75

80

85

90

95

100

105

Suct. 

Press.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

131 269 138

133 272 143 293 143

135 274 148 295 148 317 147

137 278 151 298 153 319 152 341 152

139 281 153 301 156 321 157 343 157 365 157

141

305 159 325 160 345 161 367 161 389 161

143

329 164 349 165 369 165 391 166 413 166

145

352 168 373 169 393 170 415 170 437 171

147

356 172 376 173 396 174 417 174 439 175

149

379 177 400 178 420 178 441 178

151

403 182 424 183 444 183

153

427 187 447 187

155

451 192

157

Summary of Contents for 13 SEER Single Package Air Conditioner

Page 1: ...our problem call your installing contractor or distributor in your area INTRODUCTION Mostanyairconditionerwillkeepyoucool Ourairconditionerwasdesignedtodo it efficiently Efficiency means less cost to...

Page 2: ...2...

Page 3: ...rmostat at the comfort level you wish and then leave it alone Let it control the operation of the air conditioning system If you get chilly turn it up a degree at a time until comfort is restored 3 It...

Page 4: ...al supply should be checked to de termine if adequate power is available If there is any question concerning the power supply contact the local power company Inspecting Equipment All units are securel...

Page 5: ...ervicing and air circulation Do NOT install unit in a confined or recessed areathatwillallowdischargeairfromtheunit to re circulate into the condenser air inlet through the coil Service Access Clearan...

Page 6: ...how the floor joist location willaffectcuttingtheopeningneededforthebox Floor joists generally are located on 16 centers leaving 14 3 8 between joists After measuring the return air box approximately...

Page 7: ...performance of an air conditioning system than any other factor The duct must be sufficientlylargetoconductanadequateamount of air to each register Air ducts should be installed in accordance with the...

Page 8: ...to the corresponding fittings with the clamps pro vided with the ducts Note All connections should be leak tight or a loss in cooling capacity will result c Theflexibleductsmaybecuttotherequired leng...

Page 9: ...low wires from the unit to the R and Y terminals respectively on thethermostatsubbase Connectthegreen wire to the yellow wire at the unit See the instructionsheetpackedwiththethermostat for detailed m...

Page 10: ...nctions correctly h Dial the thermostat higher than room tem perature The unit should stop i If using a combination heating cooling ther mostat set to the HEAT position Proceed to check for correct fu...

Page 11: ...142 331 140 144 278 147 296 147 313 147 333 144 353 142 146 299 151 317 150 335 148 355 146 375 144 148 321 153 339 152 357 150 377 148 397 147 150 324 157 342 156 360 154 379 152 399 150 152 346 160...

Page 12: ...0 417 169 440 167 149 379 175 400 174 421 173 442 171 151 403 178 424 177 445 175 153 427 181 448 180 155 452 184 157 3 5 OUTDOOR TEMPERATURE F TON 70 75 80 85 90 95 100 105 Suct Press Liq Press Dis T...

Page 13: ...76 433 176 455 176 149 394 180 415 180 436 181 457 180 151 418 185 439 185 461 185 153 443 189 464 189 155 467 194 157 5 OUTDOOR TEMPERATURE F TON 70 75 80 85 90 95 100 105 Suct Press Liq Press Dis Te...

Page 14: ...er le courant avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE Pack...

Page 15: ...ployez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE Packaged Air Conditioner Single Phase NOTES 1 D...