13

13 SEER - Charging Charts - Continued

4

OUTDOOR TEMPERATURE  (°F)

TON

70

75

80

85

90

95

100

105

Suct. 

Press.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

131 281 142

133 283 147 306 146

135 285 152 308 151 330 151

137 289 155 310 156 332 155 355 155

139 292 158 313 159 334 160 357 160 379 160

141

317 162 338 164 359 164 381 164 404 164

143

341 167 362 168 384 168 406 168 429 168

145

366 172 387 172 408 172 431 172 453 173

147

369 175 390 176 412 176 433 176 455 176

149

394 180 415 180 436 181 457 180

151

418 185 439 185 461 185

153

443 189 464 189

155

467 194

157

5

OUTDOOR TEMPERATURE  (°F)

TON

70

75

80

85

90

95

100

105

Suct. 

Press.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

Liq. 

Press.

Dis. 

Temp.

129 279 140

131 281 145 304 144

133 283 150 306 149 329 148

135 287 152 308 154 331 153 353 153

137 291 155 312 157 333 158 356 157 378 157

139

315 160 337 161 358 162 380 161 403 161

141

340 164 361 165 382 166 405 165 428 166

143

365 169 386 169 407 170 430 170 453 170

145

368 173 389 173 411 174 432 174 455 174

147

393 177 414 178 435 178 457 178

149

417 182 439 182 460 182

151

442 186 463 186

153

467 191

155

Summary of Contents for 13 SEER Single Package Air Conditioner

Page 1: ...our problem call your installing contractor or distributor in your area INTRODUCTION Mostanyairconditionerwillkeepyoucool Ourairconditionerwasdesignedtodo it efficiently Efficiency means less cost to...

Page 2: ...2...

Page 3: ...rmostat at the comfort level you wish and then leave it alone Let it control the operation of the air conditioning system If you get chilly turn it up a degree at a time until comfort is restored 3 It...

Page 4: ...al supply should be checked to de termine if adequate power is available If there is any question concerning the power supply contact the local power company Inspecting Equipment All units are securel...

Page 5: ...ervicing and air circulation Do NOT install unit in a confined or recessed areathatwillallowdischargeairfromtheunit to re circulate into the condenser air inlet through the coil Service Access Clearan...

Page 6: ...how the floor joist location willaffectcuttingtheopeningneededforthebox Floor joists generally are located on 16 centers leaving 14 3 8 between joists After measuring the return air box approximately...

Page 7: ...performance of an air conditioning system than any other factor The duct must be sufficientlylargetoconductanadequateamount of air to each register Air ducts should be installed in accordance with the...

Page 8: ...to the corresponding fittings with the clamps pro vided with the ducts Note All connections should be leak tight or a loss in cooling capacity will result c Theflexibleductsmaybecuttotherequired leng...

Page 9: ...low wires from the unit to the R and Y terminals respectively on thethermostatsubbase Connectthegreen wire to the yellow wire at the unit See the instructionsheetpackedwiththethermostat for detailed m...

Page 10: ...nctions correctly h Dial the thermostat higher than room tem perature The unit should stop i If using a combination heating cooling ther mostat set to the HEAT position Proceed to check for correct fu...

Page 11: ...142 331 140 144 278 147 296 147 313 147 333 144 353 142 146 299 151 317 150 335 148 355 146 375 144 148 321 153 339 152 357 150 377 148 397 147 150 324 157 342 156 360 154 379 152 399 150 152 346 160...

Page 12: ...0 417 169 440 167 149 379 175 400 174 421 173 442 171 151 403 178 424 177 445 175 153 427 181 448 180 155 452 184 157 3 5 OUTDOOR TEMPERATURE F TON 70 75 80 85 90 95 100 105 Suct Press Liq Press Dis T...

Page 13: ...76 433 176 455 176 149 394 180 415 180 436 181 457 180 151 418 185 439 185 461 185 153 443 189 464 189 155 467 194 157 5 OUTDOOR TEMPERATURE F TON 70 75 80 85 90 95 100 105 Suct Press Liq Press Dis Te...

Page 14: ...er le courant avant de faire letretien 2 Employez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE Pack...

Page 15: ...ployez uniquement des conducteurs en cuivre 3 Ne convient pas aux installations de plus de 150 V a la terre FIELD WIRING LEGEND LOW VOLTAGE HIGH VOLTAGE Packaged Air Conditioner Single Phase NOTES 1 D...

Page 16: ...ations and illustrations subject to change without notice and without incurring obligations Printed in U S A 06 08 708901 7089010 INSTALLER PLEASE LEAVE THESE INSTALLATION INSTRUCTIONS WITH THE HOMEOW...

Reviews: