Use the following procedures to check the resistance and continuity of
the gun and its components. Perform each of these checks on a weekly
basis in the order that they are listed.
Gun Resistance
See Figure 5-2.
1. Disconnect the gun cable from the spray gun.
2. Connect the shorting plug connector (1) to the gun cable
connector (2).
3. Connect the megohm meter (4) probes to the shorting plug ring tong
terminal and gun electrode (3). If the reading is infinite, reverse the
probes.
4. Check the megohm meter reading. Resistance should be between
150 and 220 M
Ω
at 500 Volts.
5. If the reading is not between 150 and 220 M
Ω
, perform the
Multiplier
Assembly Resistance and Electrode Assembly Resistance
procedures in this section.
3146006B
1
4
3
2
Fig. 5-2
Checking Resistance Across the Gun
1. Shorting plug connector
2. Cable connector
3. Electrode
4. Megohm meter
Note: Gun shown without hose support bracket for clarity.
Gun Resistance and
Continuity Checks
Summary of Contents for Sure Coat Series
Page 8: ...Safety 1 0 2000 Nordson Corporation All rights reserved Issued 7 00 S1EN 03 SF Powder 6 ...
Page 28: ...Operation 4 0 2001 Nordson Corporation All rights reserved 334 627B Issued 3 01 Manual 31 46 ...
Page 34: ...Operation 4 6 2001 Nordson Corporation All rights reserved 334 627B Issued 3 01 Manual 31 46 ...
Page 46: ...Repair 6 0 2001 Nordson Corporation All rights reserved 334 627B Issued 3 01 Manual 31 46 ...
Page 56: ...Parts 7 0 2001 Nordson Corporation All rights reserved 334 627B Issued 3 01 Manual 31 46 ...
Page 66: ......