Fulfill
Retrofit for Mesa
Melters
30
Part 1121938_02
2013
Nordson Corporation
Troubleshooting
NOTE:
Refer to
Appendix A, Retrofit Refill System With Nordson Level Sensor,
for updated
information.
Problem
Possible Cause
Corrective Action
1.
System overfilled
Solenoid stuck open
Clean or replace.
Sensor ground wire not connected
Connect.
Refill board not working
Replace if defective. See
Refill PCA
Troubleshooting Instructions
shown
later in the
Troubleshooting
section.
Sensor not calibrated properly
Calibrate the sensor. Refer to
Level
Sensor Adjustment and Calibration
provided earlier.
2.
System underfilled
No adhesive
Add adhesive.
No power
Ensure that power is available to the
system.
Adhesive bridging
Dislodge adhesive. Add optional
vibrator kit if problem persists.
Clogged wand/hose/lid
Inspect the parts for improper
connections, clogs or kinks. Replace
as needed.
Clogged filter sock
Replace if needed.
No/low air pressure
Verify that sufficient air pressure and
flowrate is supplied to the Fulfill unit
from your factory. Static pressure
should be 65 psi min.; operating
pressure should be 45 psi min.
Replace the regulator if defective.
No power to the level sensor
Verify that power is being supplied to
the level sensor (LED not lit = no
power) and that the power cord is
installed properly.
Deflector bent
Repair or replace.
No power to fill board
Verify power to the control box and at
the board. Replace if needed.
Solenoid failure
Verify the connections to the
solenoid. Replace if defective.
Bad fill board
Replace. See
Refill PCA
Troubleshooting Instructions
shown
later in the
Troubleshooting
section.
Overfill timer too short
Adjust timer.
Sensor not calibrated properly
Calibrate the sensor. Refer to
Level
Sensor Adjustment and Calibration
provided earlier.
3.
Frequent overfill
alarms with no cause
Timers not properly set
Adjust the timer settings. See
Time
Settings
provided earlier.
Summary of Contents for Mesa Fulfill