Install the Tank Lid Components
1. See Figure 12. Install the new tank gasket (1) onto the melter tank.
2. Install the new lid support (2) using existing screws.
NOTE:
Position the level sensor probe with the fill line 2 inches from the
bottom of the probe holder. The level can be reduced by loosening the
holder's hex nut, and then sliding the probe lower. Tighten the nut to keep the
probe from moving.
3. Mount the level sensor bracket (3) onto the lid support. Secure with the
two nuts (4) and washers (5) provided.
1
4
5
3
2
6
Figure
12
Installing the tank components
4. Place the Fulfill lid assembly (6) onto the top of the melter.
5. Secure the lid by screwing the thumb screws on top of the lid into the
threaded holes in the lid support (2).