Operation
4-19
Part 1032059B
E
2003 Nordson Corporation
Manual 41-DURABLUE-MA-02
If you enter a valid set-point temperature for a
hose/gun that is not connected to the melter
or if you enter a set-point temperature that is
out of range, the right display will indicate
dashes (----) for three seconds and then
change back to the original
set-point temperature.
When the right display is flashing, you can
quickly change the current set-point
temperature to 0 degrees (off) by
simultaneously pressing both of right-display
scroll keys.
After removing a hose or a gun, use
the individual component method of set-point
temperature adjustment to set the
component’s temperature to zero degrees
(off). This will avoid causing an F1 fault when
a hose or gun is added, use the individual
component method to set the desired
temperature.
The factory set-point temperature of the
tank is 175
_
C (350
_
F). The factory
set-point temperature of all others
components is zero degrees (off).
When the units of temperature is set
to degrees Celsius, the minimum and
maximum set-point temperatures are 40
_
C
and 230
_
C. When the units of temperature
are set to degrees Fahrenheit, the minimum
and maximum set-point temperatures are 100
_
F and 450
_
F.
When using the scroll keys to adjust a
set-point temperature, the right
display automatically increments between
0, 175, and 230
_
C or between 0, 350,
and 450
_
F.
The melter will exit the setup mode and return
to the automatic scan mode two minutes after
the last key is pressed.
A global set-point temperature of zero
degrees (Celsius or Fahrenheit) turns all
components off.
When scrolling through component
numbers in the left display, component
numbers that are associated with unused
hose/gun receptacles are skipped.
The melter stores a record of the last
ten changes made to the set-point
temperatures (and operating parameters) in
the change history log.
Section 3, Installation, Review
Parameter and Set-point
Temperature Changes
Summary of Contents for DuraBlue D10L
Page 91: ...Troubleshooting 6 11 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 93: ...Troubleshooting 6 13 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 95: ...Troubleshooting 6 15 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 97: ...Troubleshooting 6 17 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 99: ...Troubleshooting 6 19 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 101: ...Troubleshooting 6 21 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 103: ...Troubleshooting 6 23 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 105: ...Troubleshooting 6 25 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 107: ...Troubleshooting 6 27 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 109: ...Troubleshooting 6 29 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 111: ...Troubleshooting 6 31 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 113: ...Troubleshooting 6 33 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...
Page 115: ...Troubleshooting 6 35 Part 1032059B E 2003 Nordson Corporation Manual 41 DURABLUE MA 02...