Program example 2
Channel 1:
Linking lines to blocks (lines 1 and 2, lines 3 and 4, lines 5 and 6, lines 7 and 6, lines 8 and 7), one pulse per line;
adjustable range = +/- 0% (meaning that manually changing a parameter via the PICO controller menu is not
possible); no delay between the linked lines (connecting time = 0) and no external continuous signal (ext.puls = 0);
each block and each linked (attached) line can be started individually (with IN1 to IN9); in line 9 the pause time v
= variable, i.e., the duration is varied between 0.12 ms and delay time via the analog input signal; the dispensing
sequences end when connected line = 0 is reached (always after lines 2, 4, 6, and 9 are completed)
Channel 2:
Parameters mostly the same as channel 1, but all individual, unlinked lines with five pulses each; no external
continuous signal (ext. pulse = 0); each line is started individually (with IN1 to IN9) and is ended automatically after
five pulses (connected line = 0)
[Device]
PDA2+2
[HW Revision] 2.2
[SW Revision] 2.2
[Filename]
PDA2_example_02.txt
[Description]
This is a PDA2+2 generated file.
(NOTE: Any text can be added as a comment; square brackets are not permitted.)
[Data]
Code 000000
Valve-no.
Ventil-Nr. 1
container
limit
adjustable range
temperature
stop
Gebinde, voll Grenzrestmenge
Einstellbereich
Temperatur
Stop
Delay-Time
1000.00
100.00
0
35.0
1
500.00
line
dosing time
pausetime
number of runs IN
connected line connecting time blocknumber dosing value ext.puls
Zeile
Dosierzeit
Pausenzeit
Pulsanzahl
IN
V-Zeile
Verz.-Zeit
Blockanzahl Menge ext.Dauers.
1
0.05
10.00
1
1 2
0
1
0.05
0
2
0.10
10.00
1
2 0
0
1
0.10
0
3
0.20
10.00
1
3 4
0
1
0.20
0
4
0.40
10.00
1
4 0
0
1
0.40
0
5
0.80
10.00
1
5 6
0
1
0.80
0
6
1.60
10.00
1
6 0
0
1
1.60
0
7
3.20
10.00
1
7 6
0
1
3.20
0
8
6.40
10.00
1
8 7
0
1
6.40
0
9
12.80
v
1
9 0
0
1
12.80
0
Valve-no.
Ventil-Nr. 2
container
limit
adjustable range
temperature
stop
Gebinde, voll Grenzrestmenge
Einstellbereich
Temperatur
Stop
Delay-Time
1000.00
100.00
0
35.0
1
0.00
line
dosing time
pausetime
number of runs IN
connected line connecting time blocknumber dosing value ext.puls
Zeile
Dosierzeit
Pausenzeit
Pulsanzahl
IN
V-Zeile
Verz.-Zeit
Blockanzahl Menge ext.Dauers.
1
0.05
10.00
5
1 0
0
1
0.05
0
2
0.10
10.00
5
2 0
0
1
0.10
0
3
0.20
10.00
5
3 0
0
1
0.20
0
4
0.40
10.00
5
4 0
0
1
0.40
0
5
0.80
10.00
5
5 0
0
1
0.80
0
6
1.60
10.00
5
6 0
0
1
1.60
0
7
3.20
10.00
5
7 0
0
1
3.20
0
8
6.40
10.00
5
8 0
0
1
6.40
0
9
12.80
10.00
5
9 0
0
1
12.80
0
[Data End]
Program Examples (continued)
PICO Controller 2+2-XCH-V2
38
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.