Menu Tree
Cabin 1
Determining whether the settings of Cabin 1 should be displayed on the SPA display.
– Enable: Display enabled ("On") or disabled ("Off").
– Server ID: Determining of the CAN BUS ID of the SPA control board or the Omega control
board.
– Subindex: If the system mode is set to "Wellness Dual", subindexes must be assigned for
the individual cabins.
Cabin 2
Determining whether the settings of Cabin 2 should be displayed on the SPA display.
– Enable: Display enabled ("On") or disabled ("Off").
– Server ID: Determining of the CAN BUS ID of the SPA control board or the Omega control
board.
– Subindex: If the system mode is set to "Wellness Dual", subindexes must be assigned for
the individual cabins.
Steam Generator 1
Determining whether the settings of the steam generator 1 should be displayed on the SPA display.
– Enable: Display enabled ("On") or disabled ("Off").
– Server ID: Determining of the CAN BUS ID of the Nordmann Omega control board.
Steam Generator 2
Determining whether the settings of the steam generator 2 should be displayed on the SPA display.
– Enable: Display enabled ("On") or disabled ("Off").
– Server ID: Determining of the CAN BUS ID of the Nordmann Omega control board.
Diagnostic
Determining which control boards should be displayed in diagnostic mode on the SPA display.
– Server ID 0: Display enabled ("On") or disabled ("Off").
– Server ID 1: Display enabled ("On") or disabled ("Off").
– Server ID 2: Display enabled ("On") or disabled ("Off").
– Server ID 3: Display enabled ("On") or disabled ("Off").
– Server ID 4: Display enabled ("On") or disabled ("Off")).
– Server ID 5: Display enabled ("On") or disabled ("Off").
– Server ID 6: Display enabled ("On") or disabled ("Off")).
– Server ID 7: Display enabled ("On") or disabled ("Off").
IP Settings
Host Name Suffix
Determining of the host name suffix.
DHCP Mode
Determining whether DHCP mode should be used ("On") or not ("Off").
IP Address
Determining of the static IP address of the Nordmann Omega or the Condair Delta SPA Control Box.
Subnet Mask
Determining of the subnet mask for IP communication.
Gateway
Determining of the Gateway IP address of the Nordmann Omega or the Condair Delta SPA
Control Box.
DNS Primary
Determining of the IP Address of the primary domain name server (DNS).
The IP address for the primary domain name server is used when DHCP mode is off.
DNS Secondary
Determining of the IP Address of the secondary domain name server (DNS).
The IP address for the secondary domain name server is used when DHCP mode is off.
Diag. Board ID 0 .... Diag. Board ID 7
Note
: Only the boards that were selected in the menu tree appear under Diagnostics.
Output Sensor Setup
Diagnostics of the settings for the sensor inputs.
– Demand Select: Switching between current and voltage measurement.
– Humidity Select: Switching between current and voltage measurement.
– Temp. Control: Switching between different sensor types.
– Temp Gain: Switching the input gain of the temperature sensor.
– Bench Temp. Control: Switching between different sensor types.
– Bench Temp. Gain: Switching the input gain of the bench temperature sensor.
Output Relay
Diagnostics of the relay outputs.
– Sec. Contactor: Switching the safety contactor on and off.
– Inlet Valve: Switching the inlet valve of the Nordmann Omega on and off.
– Relay Drain: Switching the relay of the drain pump of the Nordmann Omega on and off.
– Relay Fan 1: Switching the relay of fan 1 on and off.
– Relay Fan 2: Switching the relay of fan 2 on and off.
– Relay 8: Switching the additional relay 8 on and off.
– Relay 9: Switching the additional relay 9 on and off.
– Relay Error: Switching the error relay on and off (Err Out).
– Relay Light 1: Switching the relay of Light 1 on and off.
– Relay Light 2: Switching the relay of Light 2 on and off.
– Relay Pump 1: Switching the relay of Pump 1/Valve 1 on and off.
– Relay Pump 2: Switching the relay of Pump 2 on and off.