HOW TO PUT ON THE CHEST PULSE SENSOR
The chest pulse sensor has two components: a chest
strap and a sensor unit (see the drawing below). Insert
the tab on one end of the chest strap into one end of
the sensor unit, as shown in the inset drawing. Press
the end of the sensor unit under the buckle on the
chest strap. The tab should be flush with the front of
the sensor unit.
Next, wrap the
chest pulse sen-
sor around your
chest and attach
the other end of
the chest strap to
the sensor unit.
Adjust the length
of the chest strap,
if necessary. The
chest pulse sensor should be under your clothes, tight
against your skin, and as high under the pectoral mus-
cles or breasts as is comfortable. Make sure that the
logo on the sensor unit is facing forward and is right-
side-up.
Pull the sensor unit away from your body a few inches
and locate the two electrode areas on the inner side
(the electrode areas are covered by shallow ridges).
Using saline solution such as saliva or contact lens
solution, wet both electrode areas. Return the sensor
unit to a position against your chest.
CHEST PULSE SENSOR CARE
• Dry the chest pulse sensor after each use. The
chest pulse sensor is activated when you wet the
electrode areas and put on the chest pulse sensor;
the chest pulse sensor shuts off when it is removed
and the electrode areas are dried. If the chest pulse
sensor is not dried after each use, the battery may
be drained prematurely.
• Store the chest pulse sensor in a warm, dry place.
Do not store the chest pulse sensor in a plastic bag
or other container that may trap moisture.
• Do not expose the chest pulse sensor to direct sun-
light for extended periods of time or to temperatures
above 122° F (50° C) or below 14° F (-10° C).
• Do not excessively bend or stretch the sensor unit
when using or storing the chest pulse sensor.
• Clean the sensor unit using a damp cloth—never
use alcohol, abrasives, or chemicals. Hand wash
and air dry the chest pulse sensor.
CHEST PULSE SENSOR TROUBLESHOOTING
If the chest pulse sensor does not function prop-
erly, try the steps below.
• Make sure that you are wearing the chest pulse sen-
sor as described at the left. Note: If the chest pulse
sensor does not function when positioned as
described, move it slightly lower or higher.
• Use saline solution such as saliva or contact lens
solution to wet the two electrode areas on the sen-
sor unit. If heart rate readings do not appear until
you begin perspiring, re-wet the electrode areas.
• Position yourself near the console.
For the console
to display heart rate readings, the user must be
within armʼs length of the console.
• The chest pulse sensor is designed to work with
people who have normal heart rhythms. Heart rate
reading problems may be caused by medical condi-
tions such as premature ventricular contractions
(pvcs), tachycardia bursts, and arrhythmia.
• The operation of the chest pulse sensor can be
affected by magnetic interference caused by high
power lines or other sources. If it is suspected that
this is a problem, try relocating the elliptical strider.
12
HOW TO USE THE CHEST PULSE SENSOR
Chest Strap
Sensor Unit
Tab
Buckle
Sensor
Unit
Logo