5 Parameterisation
BU 0280 GB
Subject to technical amendments
55
Parameter
{Factory setting}
Setting value / Description / Note
Device
Supervisor
Parameter
set
P741
...
[-01]
...
...
[-10]
Process data bus Out
S
0000 ... FFFF (hex)
This parameter provides information about the actual status word and the actual values that are
transferred via the bus systems.
... [-01 ]
= Status word
Status word, source from P509.
... [-02]
= Actual value 1 (P543)
... [-03]
= Actual value 2 (P544)
... [-04]
= Actual value 3 (P545)
... [-05] =
Bus I/O Out Bit (P481)
The displayed value depicts all Bus Out Bit sources
linked with
or
.
... [-06 ]
= Parameter data Out 1
... [-07 ]
= Parameter data Out 2
... [-08]
= Parameter data Out 3
... [-09]
= Parameter data Out 4
... [-10] =
Parameter data Out 5
Data during parameter transfer.
P748
System bus status
0000 ... FFFF (hex)
or
0 ... 65535 (dec)
Shows the status of the system bus.
Bit 0
Bit 1
Bit 2
Bit 3 ... 5:
Bit 6
Bit 7
Bit 8
Bit 9
Bit 10
24V Bus supply voltage
CANbus in "Bus Warning" status
CANbus in "Bus Off" status
Vacant
The protocol of the CAN module is 0 = CAN / 1 = CANopen
Vacant
"Bootsup Message" sent
CANopen NMT state
CANopen NMT state
CANopen NMT state
Bit 10
Bit 9
Stopped
Pre-Operational
Operational
0
0
1
0
1
0
P749 DIP
switch
status
0000 ... 00FF (hex)
or
0 ... 255 (dec)
This parameter shows the current setting of the FI DIP switch (Section 2.2.3).
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
DIP switch 1
DIP switch 2
DIP switch 3
DIP switch 4
DIP switch 5
DIP switch 6
DIP switch 7
DIP switch 8