P734
Phase W current
(W phase current)
S
0.0 ... 999.9 A
Displays the actual W phase current.
NOTE:
This value can deviate somewhat from the value in P719, due to the measurement procedure
used, even with symmetrical output currents.
Pos: 413 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P735 – Drehzahl Drehgeber [SK 500...535E] @ 0\mod_1328173917158_388.docx @ 13146 @ @ 1
P735
Speed encoder
(Speed encoder)
SK 520E or
higher
S
-9999 ... 9999 rpm
Displays the actual rotation speed supplied by the incremental encoder. For this, P301 must be
correctly set.
Pos: 415 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P736 – Zwischenkreisspannung @ 0\mod_1328174969216_388.docx @ 13192 @ @ 1
P736
D.c. link voltage
(DC link voltage)
0 ... 1000 V DC
Displays the actual link voltage.
Pos: 416 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P737 – Aktuelle Auslastung Bremswiderstand @ 0\mod_1328175007763_388.docx @ 13215 @ @ 1
P737
Usage rate brakeres.
(Actual brake resistor usage rate)
0 ... 1000 %
This parameter provides information about the actual degree of modulation of the brake chopper
or the current utilisation of the braking resistor in generator mode.
If parameters P556 and P557 are correctly set, the utilisation related to P557, the resistor power,
is displayed.
If only P556 is correctly set (P557=0), the degree of modulation of the brake chopper is displayed.
Here, 100 means that the brake resistor is fully switched. On the other hand, 0 means that the
brake chopper is not active at present.
If P556 = 0 and P557 = 0, this parameter also provides information about the degree of
modulation of the brake chopper in the FI.
Pos: 417 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P738 – Aktuelle Auslastung Motor @ 0\mod_1328175060231_388.docx @ 13238 @ @ 1
P738
Usage rate motor
(Actual utilisation of motor)
0 ... 1000 %
Shows the actual motor load. Basis for calculation is the motor data P203. The actually recorded
current is related to the nominal motor current.
Pos: 418 /Anleitungen/Elektronik/FU und Starter/5. Parameter/Parameterauflistung (P000 ...)/P700-P799/Parameter P739 – Aktuelle Temperatur Kühlkörper [SK 500...535E] @ 0\mod_1328175099825_388.docx @ 13261 @ @ 1
P739
Heat sink temp.
(Actual temperature of heat sink)
0 ... 150 °C.
Displays the actual temperature of the FI heat sink. This value is used for overtemperature switch-
off (E001).