The interrupter’s sole job is to cut off the gas supply, whenever the fridge is not being used in 

Propane

 

mode. The new relay will do the same task, but with guaranteed success, because it too will be energized by 

the 

Propane

 button, but disabling the gas valve when the panel control is off or put in other modes. 

 

Below is a description of how to install this auxiliary relay and fix the flame sustaining issue. 

 

 

Installing the Relay 

You need a relay with a 12VDC coil that is SPST, N.O. contact, also referred to as a ‘1 Form A’ type. 

If you have a 12VDC coil relay, with any ‘normally open’ contacts, use it.  

Below are some suggested resources for parts. 

 

Radio Shack

 

12VDC/30A or 40A, SPST Automotive Relay 

 

Model: 275-001 or 275-226 

 

~ $7 US, online 

 

(handy, because it has a screw mounting tab and spade lugs for wiring it in – recommended) 

 

(contact current rating is not important because this circuit carries a very small current) 

 

Model XX-SRS relay socket to go with above relays, if you want to plug the relay into a socket 

instead of using female spade lugs plugged directly onto the relay’s lugs. (Extra fluff.) 

 

~$6 US, online 

 

Any of the other 12VDC relays on their web site will work, but will require soldering the wires to 

solder lugs or pins. The better, simpler way is to use crimped-on, Quick-connect, spade lugs. 

 

Digi-Key

On the relay page, apply a filter for ‘12VDC’, ‘Automotive’, and ‘Quick-connect’ to take you 

directly to the type needed. 

 

Some recommended part numbers: 

PB685-ND, $2.59 US, online 

255-1828-ND, $4.30 US, online 

and any others of this type will work. 

 

You may find one at your local auto parts store. Buy it and save on shipping. Remember, it only needs to 

have a 12V coil and one set of “normally open” contacts. Just about any auto relay will work; they are very 

common. 

 

Also helpful, is the use of 2-to-1 spade adapters, with ¼" blades, to add additional wires at Relighter 

terminals T1 and T3. Thanks goes to Paul Gloger for this suggestion. See his suggested wiring details below. 

 

Radio Shack

Quick-Disconnect Adapter Set (8-Pack) 

Catalog #: 64-3064  

$1.99 

 

Summary of Contents for 3163 Series

Page 1: ...electrical circuits that can lead to a dangerous situation it is recommended you proceed with caution No liability can be assumed for the use of these instructions To continue with these instructions...

Page 2: ...om grill beneath the fridge door looking toward the left rear corner you should be able to see the blue burner flame through a small glass window on the front of the burner box See image below You can...

Page 3: ...panel and set that panel aside 6 Unclamp and cautiously remove the hose from the barbed fitting on the bottom of the sink faucet If the faucet is made of plastic be very gentle twisting the hose loos...

Page 4: ...the side flanges of the fridge on either side of the door 13 Tape the door locking pin on the chain to the cabinet to keep it out of the way 14 Ensuring that all front screws are removed gently pull...

Page 5: ...ting on exposed metal or wires Set the wires aside on the floor 19 Pull the fridge completely out of the van and place it on a work surface It doesn t weigh much so you should be able to lift it easil...

Page 6: ...y over the flame slots The tip must be over the flame for the maximum output voltage from the thermocouple The vibration of the van may have caused the thermocouple to slip back away from the flame re...

Page 7: ...hread into the valve Why If you are brave you can attempt to rethread the valve s threads with the standard thread pitch or even riskier try to chase the threads on the valve with a new standard threa...

Page 8: ...l next be lighting the burner Be sure to have plenty of ventilation though you will only be starting the burner momentarily Keep all flammable material away from the burner box 10 Press the Propane bu...

Page 9: ...s a fix for this that eliminates the problem without replacing the relighter module The Fix The interrupter circuit inside the relighter module is supposed to go to zero ohms when the flame is detecte...

Page 10: ...ket to go with above relays if you want to plug the relay into a socket instead of using female spade lugs plugged directly onto the relay s lugs Extra fluff 6 US online Any of the other 12VDC relays...

Page 11: ...Page 11 of 15 Propane button Wiring Diagram N O 12VDC Relay coil polarity is unimportant...

Page 12: ...Page 12 of 15 Physical Connections Remove WHT wires from interrupter Insulate and set aside N O 12VDC Relay coil polarity is unimportant...

Page 13: ...Page 13 of 15 Final Drawing and Suggested Wiring Details from Paul Gloger Wiring colors above are suggested for ease of identification but other colors may be substituted...

Page 14: ...16 20 AWG automotive wire is sufficient Color is not important exercise your own creativity 6 Make sure all connections are insulated covering with electrical tape if necessary Fasten the relay to the...

Page 15: ...5 or the 6 o clock position This should bring the inside of the fridge to approximately 40 deg F 4 4 deg C 24 Change to 12V mode and ensure the inside temp stays at or lower than 40 degrees 25 Change...

Reviews: