![Norcold 121X series Service Manual Download Page 17](http://html1.mh-extra.com/html/norcold/121x-series/121x-series_service-manual_1700922017.webp)
S
ection
3
15
Figure 3-2. —Measuring DC voltage across P1-1 and P1-6 with wire harness
disconnected.
100 B
ANS
I
Z21. 2
JW5
P3
R
T424F12
12V
05-43
07
3
D5
R50
R49
07
3
07
3
07
3
4
C
Q3
4
C
D8
CPC - E
94 V - 0
P4
GND
12VDC
Potter & Brumfield
T7CS1D2-05
5VDC
0544
700514
5A@120VAC
CHINA
D3
c
4
D6
3
07
R28
R
3
D13
07
3
R39
D1
N
M
07
3
1237
0301
9
8
4
5
3
K3
R25
R27
R26
R29
C8
7
4
R
1
2
Potter & Brumfield
T77V1D10-09
CHINA
CHINA
10A@120V
AC
700514
10A@120V
AC
Potter & Brumfield
T77V1D10-09
30VDC RES.
30VDC RES.
700514
D4
R37
R34
4
6
5
D 12
D
11
Z3
C 1
Potter & Brumfield
T77V1D10-09
CHINA
10A@120V
AC
30VDC RES.
700514
JW4
JW6
D2
R9
R7
R24
R46
R4
R5
R23
R20
R18
R21
R21
JW7
JW9
JW10
JW8
R36
R41
R45
JW2
R441
R8
R10
JW3
R6
R40
R43
R42
R2
R38
R47 R30
R48
R35
R33
U1
LP1
Q1
Q2
Q6
C9
D10
R11
R12
C7
R16
R15
R17
R19
R13
R22
R32
R31
Z2
D7
R14
U4
C3
C5
U3
U6
JW1
1
Z4
MIN MAX
RANGE
HOLD
H
Hz
REL
mA
A
mV
V
V
OFF
!
!
A
COM
V
mA
µ
A
1000V MAX
400mA MAX
FUSED
10A MAX
FUSED
PEAK MIN MAX
µ
A
CAT II
4 1/2 DIGITS
1 Seconds
TRUE RMS MULTIMETER
V
V
P1-6
P1-1
10.5 to 15.4 VDC
+
12 VDC
in
–
12 VDC
in
F1 Fuse/5 Amp
100 B
ANS
I
Z21. 2
JW5
P3
R
T424F12
12V
05-43
07
3
D5
R50
R49
07
3
07
3
07
3
4
C
Q3
4
C
D8
CPC - E
94 V - 0
P4
GND
12VDC
Potter & Brumfield
T7CS1D2-05
5VDC
0544
700514
5A@120VAC
CHINA
D3
c
4
D6
3
07
R28
R
3
D13
07
3
R39
D1
N
M
07
3
1237
0301
9
8
4
5
3
K3
R25
R27
R26
R29
C8
7
4
R
1
2
Potter & Brumfield
T77V1D10-09
CHINA
CHINA
10A@120V
AC
700514
10A@120V
AC
Potter & Brumfield
T77V1D10-09
30VDC RES.
30VDC RES.
700514
D4
R37
R34
4
6
5
D 12
D
11
Z3
C 1
Potter & Brumfield
T77V1D10-09
CHINA
10A@120V
AC
30VDC RES.
700514
JW4
JW6
D2
R9
R7
R24
R46
R4
R5
R23
R20
R18
R21
R21
JW7
JW9
JW10
JW8
R36
R41
R45
JW2
R441
R8
R10
JW3
R6
R40
R43
R42
R2
R38
R47 R30
R48
R35
R33
U1
LP1
Q1
Q2
Q6
C9
D10
R11
R12
C7
R16
R15
R17
R19
R13
R22
R32
R31
Z2
D7
R14
U4
C3
C5
U3
U6
JW1
1
Z4
AC heater wires
See NOTE
MIN MAX
RANGE
HOLD
H
Hz
REL
mA
A
mV
V
V
OFF
!
!
A
COM
V
mA
µ
A
1000V MAX
400mA MAX
FUSED
10A MAX
FUSED
PEAK MIN MAX
µ
A
CAT II
4 1/2 DIGITS
1 Seconds
TRUE RMS MULTIMETER
V
V
Figure 3-3. —Measuring DC voltage across Yellow/Green and Green wires - all models.
10.5 to 15.4 VDC
Yellow/Green
Green
+
12 VDC
in
–
12 VDC
in
Summary of Contents for 121X series
Page 2: ...This page intentionally left blank...
Page 10: ...8 Section 2 This page intentionally left blank...
Page 96: ...94 Section 12 Section 12 Wiring Diagrams and Pictorials Figure 12 1 Wiring diagram...
Page 97: ...Section 12 95 Figure 12 2 Wiring pictorial...
Page 99: ...Section 12 97 This page intentionally left blank...