PAGE 2 OF 13 

 

ISSUE 1 

 

02 2006

 

 
 
 

SAFETY 

IMPORTANT:   DO NOT OPERATE THE TOOL BEFORE READING THIS HANDBOOK. FAILURE TO 

DO SO MAY RESULT IN PERSONAL INJURY OR DAMAGE TO THE TOOL. 

 
 
This tool is intended for use with threaded fasteners.  Any other use is not recommended. 
 
The use of ear protectors is recommended. 
 
Do not use tool in potentially explosive atmosphere as these tools contain grease, which may cause an 
explosion hazard in the presence of pure oxygen.  These tools also contain aluminium alloy components 
which may cause a hazard in certain explosive environments. 
 
Be aware of unexpected tool movement due to reaction forces as this may cause injuries.  Failure of the 
drive shaft may also cause unexpected tool movement. 
 
Isolate the tool from all energy sources before changing or adjusting the drive square or socket. 

 
 

There is a risk of crushing between the reaction foot and work piece. 

Keep hands away from reaction foot. 

Keep hands away from tool output. 
 
 

 
Keep loose clothing, hair, etc. from being caught in any rotating part of the tool. 
 
Ensure all hoses are correctly fitted before switching on the mains air supply.  This avoids the risk of injury 
by whipping air hoses. 
 
Use only sockets and adaptors which are in good condition and are intended for use with power tools. 
 
Pneutorque® Wrenches are non impacting, torque controlled bolt tightening tools and must always be 
operated with the following:- 

 

Clean dry air supply with a minimum flow of 19 litres/sec (40 CFM). 

 

Air Regulator and optional Lubricator Unit 1/2” Bore (12 mm). 

 

Impact or high quality sockets. 

 Reaction 

Arm. 

 

Summary of Contents for PNEUTORQUE PTME-72-1000

Page 1: ...EXTENSION PTME 72 1000 STALL TOOLS OPERATORS HANDBOOK PART NO 34305 Issue 1 ENGLISH NORBAR TORQUE TOOLS LTD Beaumont Road Banbury Oxfordshire OX16 1XJ UNITED KINGDOM Tel 44 0 1295 270333 Fax 44 0 1295...

Page 2: ......

Page 3: ...IMUM TORQUE TOOL TYPE 18064 B06 Bi directional Pneutorque stall tool with fixed nose extension PTME 72 1000 B 1000 N m Tool stalls against external regulator setting 18064 F06 Forward clockwise only P...

Page 4: ...also cause unexpected tool movement Isolate the tool from all energy sources before changing or adjusting the drive square or socket There is a risk of crushing between the reaction foot and work piec...

Page 5: ...encer 26287 Spring Pin for drive shaft 77112 2 Drive Shaft 3 4 FEATURES AND FUNCTIONS REPLACEABLE DRIVE SHAFT All tools are fitted with a 19mm drive shaft that can easily be replaced TRIGGER The trigg...

Page 6: ...F open ended spanners 2 Connect the inlet side of the Lubro control unit B to the mains air supply A using a minimum hose size of bore 12mm Avoid using bore hoses of longer than 5 meters from the sup...

Page 7: ...____________________ The tools use the air pressure set on an external pressure regulator unit to determine the stall torque Pneutorques are supplied with an Air Pressure Graph which relates torque ou...

Page 8: ...e Figure 3 WARNING EXCEEDING THE MAXIMUM AIR PRESSURE AS STATED ON THE TOOL WILL CAUSE OVERLOADING AND MAY LEAD TO SERIOUS DAMAGE WARNING CHANGING THE MAINS AIR PRESSURE AFTER SETTING THE LUBRO CONTRO...

Page 9: ...lockwise Counter clockwise Selector is correctly set 3 Rotate the Handle into a convenient position relative to the reaction foot Fit the tool onto the fastener to be tightened with the reaction foot...

Page 10: ...t adjacent to the reaction point See Figure 6 4 Adopt a suitable posture to counteract normal or unexpected movement of the tool due to reaction forces 5 Squeeze the trigger partially to bring the rea...

Page 11: ...Turmogrease Li 802 EP or equivalent good quality grease SILENCER ___________________________________________________________________ The silencer 18591 must be changed every 12 months This may be more...

Page 12: ...ove remainder of drive shaft B Again securely support the tool in a horizontal position 3 Taking new drive shaft B 77112 2 insert splined end into the reaction foot C insuring correct engagement of sp...

Page 13: ...al 7 16 kg 15 8lb 385mm x 72mm wide x 255mm min PTME 72 1000 F Forward clockwise only 6 96 kg 15 4lb 340mm x 72mm wide x 255mm min Maximum Vibration at Handle 2 5m s 2 Tested in accordance with ISO 86...

Page 14: ...PAGE 12 OF 13 ISSUE 1 02 2006...

Page 15: ...or is damaged Drive shaft sheared See maintenance section to replace Tool does not stall Tool has not achieved torque increase air pressure Fastener sheared or thread stripped Gear train or air motor...