PAGE 8 OF 13
ISSUE 1
02 2006
B. RELEASING _______________________________________________________________
1.
Fit the Pneutorque® with the correct size impact or high quality socket to suit the fastener to be
released. Ensure socket is in good condition.
2.
Ensure the clockwise/counter-clockwise selector is correctly set.
3.
Rotate the handle into a convenient position relative to the reaction foot. Fit the tool onto the fastener
to be released with the reaction foot adjacent to the reaction point. See Figure 6.
4.
Adopt a suitable posture to counteract normal or unexpected movement of the tool due to reaction
forces.
5.
Squeeze the trigger partially to bring the reaction foot into contact with the reaction point.
6.
Fully depress trigger and keep fully depressed until bolt releases.
TIP: If unable to release the bolt increase the air pressure to the tool. Do not exceed max air
pressure as stated on the tool.
WARNING:
EXCEEDING THE MAXIMUM AIR PRESSURE WILL CAUSE
OVERLOADING AND MAY LEAD TO SERIOUS DAMAGE.
WARNING:
CHANGING THE MAINS AIR PRESSURE AFTER SETTING THE
PRESSURE REGULATOR WILL CHANGE THE STALL TORQUE
VALUE.
Figure 6
Summary of Contents for PNEUTORQUE PTME-72-1000
Page 2: ......