TROUBLE SHOOTING
The following is only a guide, for more complex faults please contact your local Norbar distributor or Norbar directly.
Problem
Likely Solutions
Tool output does not rotate
when control system operated.
Check air supply is functioning & connected.
Check air pressure setting (at least 1 bar required).
Check correct setting of control system.
Output drive square sheared, see maintenance section to replace.
Gear train or air motor is damaged, return for repair.
Drive square sheared.
See maintenance section to replace.
Tool does not stall.
Tool has not achieved torque, increase air pressure.
Fastener sheared or thread stripped.
Gear train or air motor is damaged, return for repair.
GLOSSARY OF TERMS
Word or Term
Meaning
Air pressure graph
Graph to show air pressure setting for required torque.
BSP
British Standard Pipe, this is a thread size.
CFM
Cubic Feet per minute (ft³/m), a measure of air flow.
Lubro Control Unit
Unit to provide filtering and lubrication along with pressure regulation.
A Lubro Control Unit is supplied with some PneuTorques.
PT
PneuTorque
®
; the product name.
Reaction Arm
Device to counteract applied torque.
Tool Control System
Pneumatic circuit to control operation of remote PT.
Velocity Ratio
The gearing ratio of the PT.
XAUT
Auto Two speed. X = Remote.
XMTS
Manual Two Speed. X = Remote.
21
Summary of Contents for 16011.X
Page 21: ...20...