10
When installing the UC4+
sensors (E02), start with the
smallest serial number on the left
hand side proceeding to the
largest serial number on the right
hand side (Figure 9).
5.
Sensor cables should run through the
mounting bracket tube and then behind
the member the bracket is mounted
onto. Cable-tie the connector in place.
The cable must not be allowed to hang
below the boom (
Figure 6
).
Figure 6: Another Acceptable
Mounting
Avoid mounting sensors in
locations where they may read
from parts of the boom as shown
in Figure 7.
Figure 7: Poor Mounting
(Sensor reading off boom)
General mounting rules for UC4+
ultrasonic wing sensors:
a)
In its lowest position, the sensor mouth
must be 9 inches or more from the
ground.
b)
The bottom of the sensor must be at
least 9 inches in front of the spray
nozzles.
c)
The bottom of the sensor must be at
least 9 inches above the spray nozzles.
d)
Ensure that there are no obstructions
within a 12-inch diameter circle
projected directly below the center of
the sensor.
e)
The sensor should be approximately
vertical at normal operating heights.
Figure 8: Sensor Mounting Guidelines
A
B
B
D
C
Ultrasonic
Acoustic Cone
Summary of Contents for UC4+ Apache 2010+
Page 9: ...6 Figure 3 Hydraulic Plumbing Schematic ...
Page 28: ...25 5 ELECTRICAL REFERENCE CABLE DRAWINGS 5 1 ITEM C02 44668 CABLE SENSOR BRANCH ...
Page 29: ...26 5 2 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL ...
Page 30: ...27 5 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Page 31: ...28 5 4 ITEM C05 44674 CABLE UC4 SENSOR ROLL BIAS ...
Page 32: ...29 5 5 ITEM C10 44650 39 CABLE POWER GENERIC SELF PROPELLED L 100 2 54m ...
Page 33: ...30 5 6 ITEM C11 44651 03 CABLE VALVE EXTENSION GENERIC 365 9 27m ...
Page 34: ...31 5 7 ITEM C12 44658 91 CABLE UC4 VALVE AP3 MAIN ...
Page 35: ...32 5 8 ITEM C13 44658 90 CABLE UC4 SENSE AP3 ...
Page 36: ...33 5 9 ITEM C14 44658 99 CABLE UC4 INTERFACE POWER PIGTAIL FUSED ...