7
4
INSTALLATION PROCEDURE
4.1
E
XISTING
S
YSTEM
C
HECK
It is necessary to check the existing
system’s functionality before installing the
UC4+ Spray Height Control system.
1.
Drive your sprayer onto a flat piece of
land, with unobstructed boom
movement (e.g. no power lines).
2.
Test that all boom functions operate
correctly. As you test each function
check it off in
Table 3
.
It is necessary to test the boom
functions in all directions
Table 3: Hydraulic System Function
Check Sheet
BOOM
FOLD
IN
FOLD
OUT
UP
DOWN
LEFT
MAIN
RIGHT
ROLL*
N/A
N/A
*
Some sprayers may not have this function.
4.2
B
OOM
S
PEED
T
EST
IMPORTANT:
Raise/lower all boom sections several
times to warm up the hydraulic
system. Grease all moving parts for
consistent results.
1.
Lower each boom and main section as
close to the ground as possible.
2.
Set your sprayer at field working RPM
on the throttle and mark this value in
Table 4
.
You will need a stopwatch or a
watch that displays “seconds” for
the next step.
3.
Raise the LEFT boom from its extreme
LOW position to the very TOP of its
travel. Record the time this takes in
Table 4
,
“Trial #1” for “Left UP”.
4.
Lower the LEFT boom from its extreme
HIGH position to the BOTTOM of its
travel. Record this time in
Table 4
,
Trial #1 for “Left DOWN”.
Be careful when lowering the
booms so they don’t hit the
ground.
5.
Similarly, record two more time trials
(Trial #2 & #3) for the LEFT boom and
record in
Table 4.
6.
Repeat Steps
1
through
5
for the
RIGHT, MAIN and ROLL functions.
Your sprayer may not have a roll
feature.
7.
Average the three trials recorded for
each boom movement and record this
calculation in the “Average Time” slot in
Table 4.
8.
These “Average Times” now represent
how quickly your system can react to
manual control. In
Section 4.8
, this
procedure is repeated with the UC4+
Spray Height Control system installed
for comparison and troubleshooting
purposes.
Summary of Contents for UC4+ Apache 2010+
Page 9: ...6 Figure 3 Hydraulic Plumbing Schematic ...
Page 28: ...25 5 ELECTRICAL REFERENCE CABLE DRAWINGS 5 1 ITEM C02 44668 CABLE SENSOR BRANCH ...
Page 29: ...26 5 2 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL ...
Page 30: ...27 5 3 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT ...
Page 31: ...28 5 4 ITEM C05 44674 CABLE UC4 SENSOR ROLL BIAS ...
Page 32: ...29 5 5 ITEM C10 44650 39 CABLE POWER GENERIC SELF PROPELLED L 100 2 54m ...
Page 33: ...30 5 6 ITEM C11 44651 03 CABLE VALVE EXTENSION GENERIC 365 9 27m ...
Page 34: ...31 5 7 ITEM C12 44658 91 CABLE UC4 VALVE AP3 MAIN ...
Page 35: ...32 5 8 ITEM C13 44658 90 CABLE UC4 SENSE AP3 ...
Page 36: ...33 5 9 ITEM C14 44658 99 CABLE UC4 INTERFACE POWER PIGTAIL FUSED ...