5
NookBox
Installation Guide
Repeater
Functional Switch Block
The Functional Switch Block determines which Mode the Repeater is in.
A switch in the up position indicates the
(ON)
Mode.
Likewise, a switch in the down position indicates the
(OFF)
Mode.
DIP Switches 5, 6 and 7 are reserved.
The DIP Switch settings are only valid when the Repeater is powered. For example, DIP Switch 3 is slid to the On position when the
Repeater is turned off. When the Repeater is turned on, it will NOT enter Clear Mode. However, if the DIP Switch 3 is slid to the Off
position first, followed by sliding to the On position, the Repeater will enter Clear Mode.
Supervisory Signal
• After being learnt in to the Control Panel, the Repeater will automatically transmit Supervisory Signals every 30 to 50 minutes.
• If the Control Panel has not received the signal from the Repeater for a preset period of time, the Control Panel will indicate it on
its display to show that the Repeater is experiencing an out-of-signal problem.
How to mount the Repeater
The Repeater can be placed on the table, mounted on the wall or wherever desired. Follow the steps below to mount the Repeater:
Step 1
Using the holes of the Mounting Bracket as a template, drill holes into the mounting surface.
Step 2
Insert the wall plugs if fixing into plaster or brick. Screw the Mounting Bracket to the wall.
Step 3
Hook the Repeater onto the Wall Mounting Bracket (with the Mounting Holes of the Repeater).
Tamper Protection
• The Tamper Switch is in normal operating position (Tamper Closed) when the Repeater is hooked onto the Wall Mounting Bracket.
Tamper violation happens when the Repeater is removed from the hook where Tamper Switch is released (Tamper Opened).
• The tamper protection function can be disabled when DIP Switch 8 is slid to the ON position. It is enabled when DIP Switch 8 is slid
to the OFF position.
Function
ON
OFF
DIP Switch 1
Learn Device
Learning mode (Device)
Normal Mode
DIP Switch 2
Range or Walk Test
Walk Test Mode
Normal Mode
DIP Switch 3
Factory Reset
Clear Mode
Normal Mode
DIP Switch 4
Learn into Control Panel
Learning mode (Panel)
Normal Mode
DIP Switch 8
Tamper Function
Disable
Normal Mode (Enabled)