When the control uniti s turned on, if everything has been well connected, the gree l.e.d. TEST should flash while STOP,
FOTO, FCA, FCC e EDGE, SHOULD BE LIT ON (if the gate is close OLS is turned off). L.E.D START and PED have to be
turned off. When the control unit is turned on and the motor starts opening, it means that the control unit has been previously
turned off (tension cut off).
5
Turn on and program of the control unit
ON
CTS
2
1
4
3
6
5
8
7
10
9
If you have to set up the working time:
Turn off the control unit , close the gate
Put the dip-switch no.5 of DIPA in ON and give power supply again
Put the micro-switch no.5 in ON of DIPA, the control unit is ready to be programmed.
In this way is possible to set up the working time.
5.1 Working time memorization
Herewith the procedure for the working time memorization.
It is necessary to use the control START and PARTIAL OPENING.
These controls can be used from a device connected to the terminal boards 16-21 for opening START or 16-20 for opening
of PARTIAL OPENING (see “ CONNECTION OF AN OPENING CONTROL” and “ CONNECTION OF A PARTIAL OPENING
CONTROL) or from a memorized remote control (see “MEMORIZATION OF A REMOTE CONTROL”)
The operation can only be performed when in the CLOSED position. Starting from the initial
state of the electronic control unit, perform the operations described above, that is:
set switch DIP 5 to ON before powering the control unit.
5.2 Memorization of the working time with the OPENING CONTROL “START”
ON
CTS
2
1
4
3
6
5
8
7
10
9
1
Put in ON the micro-switch no. 5 of DIPA .
The automation is
in CLOSED POSITION
2
Press START (everything which is connected to the
input 21 or 1st channel of the remote control).
The automation
starts OPENING
3
Wait until the automation stops.
The automation STOPS
4
Let the time goes until the automation
should be open.
The automation
“PAUSE TIME”
5
Press the control START for closing.
The automation CLOSE
6
Wait until the automation stops automatically.
The automation is CLOSED
7
Put in OFF the micro-switch no.5 of DIPA to go
back to the normal status. The lamps is turning on
and the green l.e.d. go back to the normal status.
End of the operation
ON
CTS
2
1
4
3
6
5
8
7
10
9
START