START-S5PV
Technical manual
-11-
The control unit dispose of DIP A which can used to activate different functions to make the installation suitable to the
customer’s requirements and for more safety.
3
Functions and adjustment
3.1 Set up of the START control and PARTIAL OPENING of the DIP A
1-OFF 2-OFF
Each control the motor invert.
If it is en pause it recloses.
1-ON 2-OFF
When opening it ignore the controls, when closing it inverts and re-
open, when pause it recharges the pause time.
1-OFF 2-ON
When opening and when closing the motor stops and they invert at
the next control. IT DOESN’T RECLOSE AUTOMATICALLY
1-ON 2-ON
When opening and when closing the motors stop and the invert at
the next control. IT RECLOSE AUTOMATICALLY
3-ON
Inhibits
the opening
control
It inhibits the opening control if the photo-beam has been obscured
when the door is closed
ON
2
1
4
3
5
ON
2
1
4
3
5
ON
2
1
4
3
5
ON
2
1
4
3
5
ON
2
1
4
3
5
ON
CTS
2
1
4
3
6
5
8
7
10
9
3.2 COMPASS function of DIPA
DIP4 can activate the “compass function“
DIP 4 ON
Activate the COMPASS function
The output TEST-PHOTO (12-13)
activate the opening of the another control unit.
Tthe outputs for LIGHT (30-31)
can be inhibited with the STOP control (16-18)
Control board 1
Control board
2
Central 1
Central 2
light
30 - 18 stop
light
31 - 16 common
photo test 12 - 16 common
photo test 13 - 28 open
common
16 - 31 light
stop
18 - 30 light
common
16 - 12 photo test
open
28 - 13 photo test