![Nokia NSB-7 Series Service Manual Download Page 34](http://html.mh-extra.com/html/nokia/nsb-7-series/nsb-7-series_service-manual_1699335034.webp)
NSB-7
System Module
PAMS Technical Documentation
Page 20
ã
Nokia Mobile Phones Ltd.
Issue 1 06/00
NOTE: COBBA regulator is off in SLEEP mode. Its output pin may be fed from V
BB
in SLEEP mode by setting bit RFReg(5) to’1’ (default).
CCONT includes also five additional 2.8V regulators providing power to the RF section.
These regulators can be controlled either by the direct control signals from MAD or by
the RF regulator control register in CCONT which MAD can update. Below are the listed
the MAD control lines and the regulators they are controlling.
-
TxPwr controls
VTX regulator (VR5)
-
RxPwr controls
VRX regulator (VR2)
-
SynthPwr controls all the rf regulators except VR1
-
VCXOPwr controls VXO regulator (VR1)
CCONT generates also a 1.5 V reference voltage VREF to COBBA. The VREF voltage is also
used as a reference to some of the CCONT A/D converters.
In addition to the above mentioned signals MAD includes also TXP control signal which
goes to HAGAR power control block
.
The transmitter power control TXC is led from
COBBA to HAGAR.
Characteristics
Condition
Min
Typ
Max
Unit
Output current VR1-VR6
100
mA
Output current VR7
Depends on external BJT
150
mA
Output current VR7BASE
Base current limit
-10
mA
Output current VBB On
Current limit 250mA
Output current VBB Sleep
Current limit 5mA
125
1
mA
mA
Output voltage VR1-VR7
over full temperature, input
voltage and load range
2.7
2.8
2.85
V
Output voltage VBB
over full temperature, input
voltage and load range
2.7
2.8
2.85
V
Output voltage V2V
(VCORE)
Programmable:
Vout=1.3V+225mV*n
N = 0,1,2,3,4,5,6
1.30
2.65
V
Output voltage V2V
(VCORE) tolerance
-5
+5
%
Line regulation (not VBB)
F
v
10kHz, 2)
VBAT>3.15V
49
DB