Installing the Nokia IP561 Appliance
30
Nokia IP561 Security Platform Installation Guide
Figure 7 Rack-Mounting Screw Locations
Two rack-mounting positions allow you to mount the appliance either flush with the rack, or two
inches forward of the equipment rack. If the space behind the rack is insufficient, the rack-
mounting brackets can be attached further back on the side of the appliance.
Caution
During installation, do not block any ventilation openings. Doing so might result in
damage to the appliance when it is turned on.
To rack-mount the appliance
Caution
The appliance is heavy. Use care when you remove it from the packaging.
1. Remove the appliance from the packaging.
2. Optionally, remove the fan unit from the back of the appliance to lighten it.
a. Locate the fan unit and the two retaining screws that secure it on the back of the IP561.
b. Loosen the retaining screws by turning them counterclockwise.
00354gen
SLOT 1
SLOT 2
SLOT 3
SLOT 4
1
2
3
4
Rack-mounting screw locations
00353
Fan unit
Summary of Contents for IP561
Page 4: ...4 Nokia IP561 Security Platform Installation Guide ...
Page 8: ...8 Nokia IP561 Security Platform Installation Guide ...
Page 10: ...10 Nokia IP561 Security Platform Installation Guide ...
Page 12: ...12 Nokia IP561 Security Platform Installation Guide ...
Page 34: ...Installing the Nokia IP561 Appliance 34 Nokia IP561 Security Platform Installation Guide ...
Page 42: ...Performing the Initial Configuration 42 Nokia IP561 Security Platform Installation Guide ...
Page 86: ...Troubleshooting 86 Nokia IP561 Security Platform Installation Guide ...
Page 88: ...Technical Specifications 88 Nokia IP561 Security Platform Installation Guide ...
Page 92: ...Compliance Information 92 Nokia IP561 Security Platform Installation Guide ...
Page 96: ...Index 96 Nokia IP561 Security Platform Installation Guide ...