OPERATION
Nobles Strive Rider (03--09)
11
FILLING SOLUTION TANK
Fill the solution tank with hot water, 140
°
F / 60
°
C
maximum (Figure 12). The solution tank capacity is 32
gal / 121 L.
For Restorative Extraction Cleaning and Accessory
Tool Cleaning:
For best cleaning results, it is
recommended to pre-spray the carpet with a
commercially available cleaning agent rather than
adding the cleaning agent to the solution tank (Figure
13).
ATTENTION: Only use commercially available
cleaning agents in solution tank. Machine damage
due to improper agent usage will void the
manufacturer’s warranty.
For ReadySpace Cleaning:
Do not add cleaning
agents to solution tank. Cleaning agent MUST be
pre--sprayed on the carpet (Figure 13).
WARNING: Fire or Explosion Hazard. Never
Use Flammable Liquids.
FIG. 12
MACHINE OPERATION
FOR SAFETY: Do not operate machine unless
operator manual is read and understood.
PRE--OPERATION
-
FIRST TIME USE:
When extraction cleaning the
solution system must be primed.
See PRIMING
SOLUTION SYSTEM on page 24.
-
Vacuum floor and remove any large debris.
-
Check battery charge level indicator.
-
Check condition of rollers or brushes.
-
ReadySpace Cleaning: Make sure solution tank is
filled with only water, no cleaning agents.
-
Check vacuum hoses at rear of machine for proper
connection.
-
Check the brakes and steering for proper
operation.
OPERATING THE MACHINE
Before operating the machine, pre-spray the carpet with
a commercially available cleaning agent (Figure 13).
FIG. 13
FOR SAFETY: In the event of an emergency, strike
the emergency stop button to shut off all power to
the machine (Figure 23).
1
.
Adjust the seat to a comfortable operating position
and turn the key to the on ( I ) position (Figure 14).
FIG. 14
2. Select the type of cleaning by pressing the
ReadySpace cleaning button or the restorative
extraction cleaning button (Figure 15).
The hose connection indicator will blink if the
machine is not set up according to your selection.
See MACHINE SETUP on page 10.
ReadySpace
Cleaning button
Restorative
Extraction
Cleaning
button
Hose Connection
Indicator