OPERATION
Nobles Strive Rider (09--06)
27
TROUBLESHOOTING -- Continued
PROBLEM
CAUSE
SOLUTION
Poor water pickup.
Worn ReadySpace rollers
Replace rollers
Clogged vacuum shoes
Clean vacuum shoes
Vacuum shoe springs missing
(Extraction cleaning)
Replace vacuum shoe springs
Loose recovery tank drain hose cap
Tighten cap
Loose or disconnected vacuum hose
Connect hose cuffs securely
Clogged vacuum hose
Remove clogged debris
Defective vacuum hose
Replace vacuum hose
Recovery tank cover not down
Close cover
Worn tank cover gasket
Replace gasket
Excessive foam/cream appears
on the floor during ReadySpace
cleaning
Cleaning detergents were added to
solution tank
Drain and rinse out solution tank and
refill with water only. Do not add clean-
ing detergents
Unapproved pre--treatment detergent
used
Use approved pre--treatment deter-
gent
Short run time
Low battery charge
Charge batteries
Batteries need maintenance
See BATTERY MAINTENANCE.
Faulty charger
Repair or replace battery charger
Spray nozzles drip when not in
use
(See SOLUTION FLOW
DIAGRAM for reference)
Clogged spray tip filter/check valve
(Restorative Extraction spray tips)
Clean or replace spray tip filter
Clogged or faulty solution solenoid.
Clean or replace solution solenoid