Use and Maintenance Manual model “H14 V SHAPE”
28
ENGLISH
1
2
12.2 AUGER LOADING FUNCTION
OK
OK
OK
12.3 PELLET/EXTRACTION MIX
OPERATING PROCEDURE:
MENU >> SET USER >> AUGER LOADING
Access the menu by pressing key
Scroll the items to SET USER with the key
OK
Edit the switch on and switch off times, as well as
enabling the days of the week, keys
Confirm each data change using the
key and pass to the second screen of the
TIMER program.
The screen in the figure below shows setting options
for both desired room temperature and maximum
boiler-water temperature during the activation of
the time frame . It is also possible to control the
ventilation speed (if applicable) .
OK
1
2
Edit the values using the keys
Confirm each data change using the
key until you exit the program.
OK
During editing, remember that:
• to return to the previous data, without saving
the last data changed, press the key
•
if you intend changing a single datum, having ter
minated the change, press the key multiple
times until you exit the following function.
To return to the STAND-BY screen, use the
key , repeating the operation multiple times.
OK
The following function is necessary to facilitate the
switch on phase of the appliance, after accurate
cleaning was conducted of the hopper (pellet con-
tainer) to remove sawdust which, over time, is creat-
ed on the base. See the chapter “Routine mainte-
nance of the product”.
Also check you have placed pellets in the tank and
that the appliance is in the “OFF” or “FINAL CLEAN-
ING” status before starting the function.
The number expressed in seconds indicates the rota-
tion time of the auger during the loading phase.
After this time is up, the auger stops
automatically, after which the appliance
can switch on.
Access the menu by pressing key
Scroll the items to AUGER LOADING, key
Access the function by pressing key
The cleaner activates (for models with automatic
cleaning), after which pellet loading is enabled. The
display shows the time that passes up to 0, corre-
sponding to loading switch off.
The appliance, at the end of loading, goes to the
SET USER screen.
As soon as you switch on the appliance, having en-
abled the function, the system does not load an-
other pellet and uses the quantity inserted by the
function to trigger the flame. Therefore:
1 - do not shut-off the auger load and leave the
timer to shut off its activity;
2 - do NOT remove the quantity of pellets intro-
duced, using a vacuum cleaner or other tool.
The PELLET-EXTRACTION mix setting
allows you to change, with immediate effect, the
quantity of pellets loaded in the brazier and the
quantity of air inbound of the product, tested and
inspected with DIN PLUS certified pellets. If you use
other pellets or uncertified pellets, combustion
may need to be adjusted. Normally,
the change is executed on the EXTRACTION percent-
age to improve combustion; if oxygen adjustment is
not
efficient, you may need to also change the
percentage of PELLETS falling.
OPERATING PROCEDURE:
MENU >> SET USER >> P/E MIX
Access the menu by pressing key
Scroll the items to SET USER, key
Access the menu by pressing key
Scroll the items to P/E MIX with the key
Access the function by pressing key
OK
OK
OK
OK