Nivis Versa Router 1100 Titan - User Guide
v1.2
Page 74 of 111
3.9.1.4
Ports & interfaces
The following interfaces are usable on the Edge Router:
The
serial port
is used as a kernel console and emergency backup.
The Edge Router accepts
ssh 22/TCP
connections.
The Edge Router has an
http
server listening on port
80/TCP
for a Nivis-specific user Interface.
The Edge Router has an SNMP Agent listening on port
161/UDP
.
The HTTP – COAP proxy listens on port
9999/TCP
for HTTP queries.
The Edge Router utilizes the NTP protocol on port
123/UDP
to synchronize time with Internet time
servers. In order to synchronize the time with Internet time servers, port
123/UDP
must be open in both
directions to allow time synchronization.
In case of Versa Router™ 1100 Titan, the cellular data plan MUST allow access to the internet through
port 123 UDP, IN/OUT.
Not all interfaces are guaranteed to be enabled in all cases. Some may be disabled for specific applications.