P48: - - - -
Number of linearization data pairs
FACTORY DEFAULT: L( i ) = 0 r( i ) = 0
The data pairs defining the characteristic points must be entered into a table of three columns. The table can be filled with pre-calculated data or
data measured while filling the tank. Column L shows the measured level (LEV) values. Column
“r”
shows the output values assigned to the
measured level (as per
P01 (a)
).
i
L (Left column)
Level values measured
r (Right column)
Value assigned to transmit
1 0
r(1)
2 L(2)
r(2)
L(i) r(i)
nn L(nn)
r(nn)
nn+1 0
0
32 0
0
Conditions of correct programming of the data pairs
The table must always start with: L(1)= 0 and r(1)= value (assigned to 0 level)
Column L cannot contain the same values.
If the table contains less than 32 data pairs, the row after the last valuable data pair in column L must be 0.
If the above conditions are not met and P47 = 1 (table active), an error code will be displayed (see chapter: Error Codes).
Note:
for further information about programming in reference to linearization see user’s manual of the EView software and MultiCONT process controller
5.4.7.
Informational parameters
P60: - - - - Overall operating hours of the unit [h]
P61: - - - - Time elapsed since last switch-on [h]
P62: - - - - Operating hours of the relay [h]
P63: - - - - Number of switching cycles of the relay
P64: - - - - Actual temperature of the transducer [°C]
Broken loop of the thermometer will be indicated by Pt Error message that is initiated by a signal sent via HART. In this case the transmitter will
perform temperature correction corresponding to +20 °C (+68 °F).