background image

6

Fig. 6

Be careful about chips.

 Keep your hands away from the cutting area at all 

times. During drilling, there will be chips. The chips 

are sharp. The chips are rotating with the cutter. Any 

contact with the chips can cause severe injuries.

Do not touch the slug.

 Do not touch the slug. The slug is very hot. It will 

cause severe burns. Make sure that no one touches 

the slug. Make sure that there is no one below the 

work area during operation. Hot slugs will fall. Hot 

slugs can cause severe burns, other severe injuries, 

or even death. Always wear protective equipment, 

including  protective  headgear,  eye  protection, 

hearing protection, and gloves. Do not allow any 

person without protective equipment to come near 

the machine.

Do not use your hands to remove chips.

 Chips have sharp edges. Use a screwdriver to 

remove chips. If you use your hands to remove 

chips, you can be injured, even if you are wearing 

gloves. Do not use your hands to remove chips 

under any circumstances.

The cutting edge is sharp.

 The cutting edge is sharp. If you do not wear gloves, 

you will be cut. Attempting to change the cutter can 

result in severe injuries.

Do not use Cutting Oil for other purposes.

 Cutting Oil should be used only for drilling. Please 

refer  to  Section  5-5  of  this  manual  for  further 

warnings and instructions about Cutting Oil.

The  Drill  Motor  will  stop  automatically  when 

drilling operation is completed.  If the Drill Motor 

fails to stop automatically, turn off the Motor 

Switch to stop it and then contact sales agent 

from which you have purchased your machine or 

an authorized dealer near you for repair.

CAUTION

Do not use power that is generated by an engine-

driven welder.

 The use of an engine-driven welder as a power 

source may cause your magnetic driven machine to 

malfunction, Power from an engine-driven welder 

can damage the electronic circuits in your portable 

drilling machine.

Use a Proper extension cord.

 Do not use an extension cord that is too thin. Do 

not use an extension cord that is too long. Do not 

use an extension cord that is wound on a drum. 

Do not share an extension cord with other motor-

driven tools. These uses can cause voltage to drop 

and can reduce the holding power of the magnet, 

causing the machine to move during operation. This 

can decrease performance and may cause damage 

to the machine. (Fig.7)

Extension Cord

Max length

Size (nominal cross-section 

area of the conductor)

10 m (32.8ft)

Min 1.25 mm

(AWG16)

20 m (65.6ft)

Min 2 mm

2

 (AWG14)

30 m (98.4ft)

Min 3.5 mm

2

 

(AWG12)

Fig. 7

Do not use this machine on the steel material 

being electrically welded.

 When the electric welder is not properly grounded, 

electricity will run through the Atra Ace machine 

via  its  Magnet,  causing  possible  failure  or 

malfunctioning, which in turn may cause accident.

Do not force to feed cutter when drilling manually.

 Because  the  Hi-Broach  and  Jet-Broach  have 

rather thin cutting edges with less cutting pressure 

resistance as compared to twist drill, do not force to 

feed the cutter when drilling manually. 

  If you feed it with too much force, the cutter may 

break or end up with shorter life than otherwise.

Always use a compatible Pilot Pin.

 The Pilot Pin must be compatible with the cutter. An 

improper Pilot Pin may result in an accident. See 

Section 5-3 to identify compatible Pilot Pins and 

cutters. The proper Pilot Pin to be used will vary, 

depending on the type of cutter, the diameter of the 

cutter, and the length of the cutter.

Do not switch to auto while drilling in manual mode.

 When you want automatic drilling, set the machine 

Summary of Contents for ATRA ACE WA-3500

Page 1: ...Keep this manual with your machine All users of the Nitto Kohki Portable Magnetic Drilling Machine must read this manual ATRA ACE Model WA 3500 Professional Tool For One Touch Type Annular Cutter Onl...

Page 2: ...jezyku localnym CONTENTS GENERAL SAFETY RULES 2 POWER TOOL SAFETY 3 ABOUT YOUR NITTO PORTABLE MAGNETIC DRILLING MACHINE 4 1 APPLICATION 7 2 RECEIVING INSPECTION 7 3 PART NAME 8 4 FUNCTIONS OF ELECTRO...

Page 3: ...These will cause severe hearing loss injuries You must always wear Suitable hearing protection Wear respiratory protective equipment PPE Wear respiratory protective equipment PPE when working in an e...

Page 4: ...ssemble or modify your magnetic drilling machine Do not modify your magnetic drilling machine Modifications can cause accident and severe injuries All service and repairs must be performed by an autho...

Page 5: ...R NITTO PORTABLE MAGNETIC DRILLING MACHINE DANGER Do not use your portable drilling machine on the ceiling Use of the portable drilling machine on the ceiling is dangerous The machine could fall The f...

Page 6: ...er a hole Attempting to straddle a hole will reduce the power of the Magnet This will cause the work piece to come loose during operation and can cause an accident Always use a Chain to secure the mac...

Page 7: ...The use of an engine driven welder as a power source may cause your magnetic driven machine to malfunction Power from an engine driven welder can damage the electronic circuits in your portable drill...

Page 8: ...unusual Set the auto feed switch to OFF with the Rod Handle pulled out toward the operator and run the machine idly for a few minutes That should take care of initial startup failure 1 APPLICATION Thi...

Page 9: ...8 3 PART NAME Fig 8...

Page 10: ...n is re plugged into the receptacle or when power failure is restored that has occurred during operation the Drill Motor will NOT restart automatically preventing possible accident although Magnet lam...

Page 11: ...tion of oil mist or vapor may make you feel sick When diluting Cutting Oil follow the instructions per the Operation Manual Keep Cutting Oil out of reach of children Do not drink Cutting Oil 3 First A...

Page 12: ...r applications and usage The information contained herein is for your reference purpose only to which we make no warranty of any kind and for which we shall not be held responsible Preparation of Cutt...

Page 13: ...7 4 Magnet ON CAUTION Make sure the magnet is clinging to the workpiece Set the Magnet Switch to On and the magnet will be activated Fig 18 push MAGNET Fig 18 WARNING Check to see that Magnetic power...

Page 14: ...emoving Slug Do not proceed to the next operation without removing the slug from the operation just nished At the end of drilling operation slug will pop out automatically ejected by the spring operat...

Page 15: ...ower failure is restored or power supply plug is re connected turn on Motor Switch again Drill Motor stops completely in the middle of drilling operation No Cutting Oil or insuf cient Cutting Oil Incr...

Page 16: ...ssive clearance make adjustment by tightening 5 slide board adjusting screws on the side of the machine using the same torque all round so that the Drill Motor will not come down on its own weight Fig...

Page 17: ...ting screw threads without cutting new threads 4 After replacement run the machine with no load for approx 10 minutes Fig 28 Fig 29 9 OPTIONAL PARTS 9 1 Nitto Brand Cutting Oil CAUTION Use Nitto brand...

Page 18: ...e bottom face of the Blade Base is flush with the bottom face of Magnet When the bottom face of the Blade Base sticks out from the bottom face of the Magnet the magnetic force it sends out can not be...

Page 19: ...328 35 35 Part No Diameter Depth Part No Diameter Depth Part No Diameter Depth Part No Diameter Depth TK00317 26 35 TK00318 26 5 35 TK00319 27 35 TK00320 28 35 TK00321 29 35 TK00322 30 35 TK00323 31 3...

Page 20: ...66 2 632 0308 http www nittobkk com eng index htm EC DECLARATION OF CONFORMITY We hereby declare that the following our product conforms with the essential health and safety requirements of EC Directi...

Reviews: