background image

4

pipe. This will result in an explosion and severe 

injuries or death.

 Always check the grounding conductor. If you have 

any doubts about the grounding conductor contact a 

licensed electrician.

 Wiring connections to a grounding rod require the 

expertise of a licensed electrician. Do not attempt 

the wire connections yourself. Always contact a 

licensed electrician.

 Do not abuse the power cord. A damaged power 

cord can cause an electrocution. A damaged power 

cord can cause 

fires.

 Always inspect the cord. If the 

cord is damaged, do not use the magnetic drilling 

machine.

 Do not carry the machine by the cord. Do not pull 

the cord to disconnect it from a socket.

 The cord can become damaged from heat, contact 

with sharp objects or from being twisted. Always 

inspect the cord. Do not use the machine if the cord 

is damaged.

 Always use a ground fault circuit interrupter. The use 

of a ground fault circuit interrupter may be required 

by government regulations. The failure to use a 

ground fault circuit interrupter may result in electric 

shock.

 Avoid starting the magnetic drilling machine abruptly 

or unintentionally.

 Always make sure that the switch is turned off before 

connecting the power source.

 Always disconnect the power source and turn off 

the switch before setting up for work operations. 

Always  disconnect  the  power  and  turn  off  the 

switch when inspecting work. Always disconnect 

the power and turn off the switch before attempting 

any maintenance. Failure to disconnect the power 

and turn off the switch during set up, inspection 

or maintenance can cause accidents and severe 

injuries.

ABOUT YOUR NITTO PORTABLE MAGNETIC 

DRILLING MACHINE

DANGER

Do not use your portable drilling machine on the 

ceiling.

 Use of the portable drilling machine on the ceiling 

is dangerous. The machine could fall. The falling 

machine could cause severe injuries or death. (Fig.1)

Fig. 1

WARNING

Do not use the Magnet for more than five hours.

 More than 

five

 hours of uninterrupted operation may 

cause a fire. Five hours of uninterrupted operation 

generates extreme heat in the Magnet. This heat 

can cause a fire. Do not touch the Magnet. When 

the Magnet is hot, touching it will cause a severe 

burn injury. Never use the Magnet for more than 

fiv

e continuous hours. When you are not using the 

Magnet, turn the switch to the "OFF” position and 

pull the plug out of the power source.

Do not use the Drill Motor for over 30 minutes.

 Uninterrupted operation of the Drill Motor for over 30 

minutes generates heat. This heat can cause a 

fire.

 

Never use the Drill Motor for over 30 minutes. When 

you are not using the Drill Motor, turn the switch to 

the "OFF' position and pull the plug from the power 

source.

Use only on magnetic materials.

 Your  portable  drilling  machine  cannot  be  used 

on non-magnetic materials, such as aluminum, 

stainless steel, copper or alloys. The Magnet will not 

work on non-magnetic materials. Attempting to use 

the Magnet on non-magnetic materials could cause 

an accident.

Use caution during wall operation.

 When using your portable magnetic drilling machine 

on a magnetic wall, always use caution. 

 Never stand under the machine.

  * Never allow anyone to stand under the machine.

  *  Never  put  any  part  of  your  body  under  the 

machine.

  * If the machine falls, it could result in severe injury 

or death.

 Always remove cutting oil from the tank before using 

the machine on a wall. You must manually apply 

cutting oil to the cutting tool.

Summary of Contents for ATRA ACE WA-3500

Page 1: ...Keep this manual with your machine All users of the Nitto Kohki Portable Magnetic Drilling Machine must read this manual ATRA ACE Model WA 3500 Professional Tool For One Touch Type Annular Cutter Onl...

Page 2: ...jezyku localnym CONTENTS GENERAL SAFETY RULES 2 POWER TOOL SAFETY 3 ABOUT YOUR NITTO PORTABLE MAGNETIC DRILLING MACHINE 4 1 APPLICATION 7 2 RECEIVING INSPECTION 7 3 PART NAME 8 4 FUNCTIONS OF ELECTRO...

Page 3: ...These will cause severe hearing loss injuries You must always wear Suitable hearing protection Wear respiratory protective equipment PPE Wear respiratory protective equipment PPE when working in an e...

Page 4: ...ssemble or modify your magnetic drilling machine Do not modify your magnetic drilling machine Modifications can cause accident and severe injuries All service and repairs must be performed by an autho...

Page 5: ...R NITTO PORTABLE MAGNETIC DRILLING MACHINE DANGER Do not use your portable drilling machine on the ceiling Use of the portable drilling machine on the ceiling is dangerous The machine could fall The f...

Page 6: ...er a hole Attempting to straddle a hole will reduce the power of the Magnet This will cause the work piece to come loose during operation and can cause an accident Always use a Chain to secure the mac...

Page 7: ...The use of an engine driven welder as a power source may cause your magnetic driven machine to malfunction Power from an engine driven welder can damage the electronic circuits in your portable drill...

Page 8: ...unusual Set the auto feed switch to OFF with the Rod Handle pulled out toward the operator and run the machine idly for a few minutes That should take care of initial startup failure 1 APPLICATION Thi...

Page 9: ...8 3 PART NAME Fig 8...

Page 10: ...n is re plugged into the receptacle or when power failure is restored that has occurred during operation the Drill Motor will NOT restart automatically preventing possible accident although Magnet lam...

Page 11: ...tion of oil mist or vapor may make you feel sick When diluting Cutting Oil follow the instructions per the Operation Manual Keep Cutting Oil out of reach of children Do not drink Cutting Oil 3 First A...

Page 12: ...r applications and usage The information contained herein is for your reference purpose only to which we make no warranty of any kind and for which we shall not be held responsible Preparation of Cutt...

Page 13: ...7 4 Magnet ON CAUTION Make sure the magnet is clinging to the workpiece Set the Magnet Switch to On and the magnet will be activated Fig 18 push MAGNET Fig 18 WARNING Check to see that Magnetic power...

Page 14: ...emoving Slug Do not proceed to the next operation without removing the slug from the operation just nished At the end of drilling operation slug will pop out automatically ejected by the spring operat...

Page 15: ...ower failure is restored or power supply plug is re connected turn on Motor Switch again Drill Motor stops completely in the middle of drilling operation No Cutting Oil or insuf cient Cutting Oil Incr...

Page 16: ...ssive clearance make adjustment by tightening 5 slide board adjusting screws on the side of the machine using the same torque all round so that the Drill Motor will not come down on its own weight Fig...

Page 17: ...ting screw threads without cutting new threads 4 After replacement run the machine with no load for approx 10 minutes Fig 28 Fig 29 9 OPTIONAL PARTS 9 1 Nitto Brand Cutting Oil CAUTION Use Nitto brand...

Page 18: ...e bottom face of the Blade Base is flush with the bottom face of Magnet When the bottom face of the Blade Base sticks out from the bottom face of the Magnet the magnetic force it sends out can not be...

Page 19: ...328 35 35 Part No Diameter Depth Part No Diameter Depth Part No Diameter Depth Part No Diameter Depth TK00317 26 35 TK00318 26 5 35 TK00319 27 35 TK00320 28 35 TK00321 29 35 TK00322 30 35 TK00323 31 3...

Page 20: ...66 2 632 0308 http www nittobkk com eng index htm EC DECLARATION OF CONFORMITY We hereby declare that the following our product conforms with the essential health and safety requirements of EC Directi...