7.3.8 Disassembling,
cleaning
and disinfecting the combi-head
1. Push
the two pistons
out of the combi-
head.
2. Loosen
the allen bolts.
3. Remove
the APM unit
from the milkshake
motor.
4. Pull
the milkshake mo-
tor from the combi-
head with a rotating
movement.
5. Remove
the gaskets
on the back of the
combi-head.
6. Push
the non-return
valve backwards and
out of the combi-
head.
7. Remove
the O rings
from the pistons.
8. Remove
the valve
hose from the non-re-
turn valve.
9. Remove
the two
O rings from the non-
return valve.
cleaning
and
disinfecting
10.Clean
and disinfect all
components and dry
them carefully with a
clean towel (prefera-
bly paper). (see para-
graph 7.2.3)
Do not submerge the APM unit in
water, but clean it with a brush and
(moist) cloth. Otherwise it will be
seriously damaged!