Version date: March 27
th
2018
35
7
Operator Manual
NA 3338 Rapid Combi APM
7.2.4 Decalcify
The machine, the cylinder beater and all cleaned stainless steel parts of the
mixpump must be decalcified every 2
nd
and 4
th
cleaning depending on the
pollution, but at least twice a year. We advice to use to use the decalcify agent
mentioned below:
• Decalcify agent: Nissei Descaler
Decalcify the machine, the cylinder beater and all cleaned
stainless steel parts of the mixpump every 2
nd
and 4
th
cleaning
depending on the pollution, but at least twice a year.
Decalcify solution
•
Make
a solution of 1 liter Nissei Descaler and 10 litres of cold water.
7.3 (Dis)assembling, cleaning and disinfecting the machine
Please read the general instructions on cleaning and
disinfecting before starting.
7.3.1 Procedure
(Dis)assembling, cleaning and disinfecting the machine is an intensive task.
The following sequence is recommended for an effective procedure:
1.
Defrost and drain cylinder.
2.
Remove mix pump and mix tank agitator.
3.
Drain mix tank.
4.
Clean mix tank and cylinder.
5.
Decalcify the machine (every 2
nd
and 4
th
cleaning depending on the
pollution, but at least twice a year).
6.
Remove combi-head.
7.
(Dis)assemble, clean and disinfect combi-head.
8.
(Dis)assemble milkshake motor.
9.
(Dis)assemble, clean and disinfect cylinder beater and cream seal.
10.
Fit combi-head.
11.
Disinfect machine.
12.
Clean, rinse and disinfect mix pump parts.
13.
Start up machine.
14.