52 - FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300
SQUEEGEE SYSTEM
SYMPTOM TWO
Note: Test with key switch ON, Vacuum/Squeegee switch S6 OFF (raised position) and the parking brake set.
TROUBLESHOOTING GUIDE (CONTINUED)
revised 3/00
Yes
Yes
No
Yes
Squeegee tool
will not raise
On the E2 control-
ler check for 36V
at the M- & M+
output wires. The
gry/wht is (+) &
wht/brn is (-).
Check for 36V at
the M5 actuator
motor wiring har-
ness connector
(gry/wht & wht/brn)
Inside the M5
motor check conti-
nuity on the inter-
nal limit switches
& diodes
Replace the
defective M5
squeegee lift
motor
Repair or replace
the motor switch
componets as
needed
Repair the M5
motor wiring
connector.
Check for zero
volts at the
wht/blu direc-
tion input wire
to a (Pos.) bat-
tery standoff
Replace the E2
controller module
On the S6 switch
check for 36V at
the wht/grn wire
to a (Pos.) bat-
tery standoff.
Replace the S6
vac/squeegee lift
switch
No
No
No
Yes
Yes