![Nilfisk-Advance Hydro-Retriever 2052 Service Manual Download Page 21](http://html.mh-extra.com/html/nilfisk-advance/hydro-retriever-2052/hydro-retriever-2052_service-manual_1693280021.webp)
FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300 - 19
SCRUB BRUSH SYSTEM
SYMPTOM TWO
Note: Test with the key switch on, brushes down, parking brake set, seat switch closed and drive pedal slightly depressed (either FWD or REV).
Part A: Scrub Brush Motor Load Circuit Troubleshooting Guide
TROUBLESHOOTING GUIDE (CONTINUED)
revised 3/00
No
Yes
No
Yes
Yes
Scrub brushes
do not turn (see
Figure 3).
Check continuity on
the F1 (80A) brush
motor circuit breaker.
Reset or replace
the F1 (80A) brush
motor circuit
breaker.
Check for 36V at the
wire #70 output termi-
nal on the K5 brush
motor solenoid.
See part B scrub
brush control circuit
troubleshooting.
Check for 36V at
the M4 brush
motor.
Repair or replace the
M4 brush motor.
No
Check continuity on
both the #74 (neg.) &
#70 (pos.) wires to M4.