![Nilfisk-Advance Hydro-Retriever 2052 Service Manual Download Page 25](http://html.mh-extra.com/html/nilfisk-advance/hydro-retriever-2052/hydro-retriever-2052_service-manual_1693280025.webp)
FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300 - 23
SCRUB BRUSH SYSTEM
MOTOR CARBON BRUSH INSPECTION AND REMOVAL
NOTE: The carbon brushes in the scrub brush motor should be inspected once a year or 1000 hours, and any accumulated dust blown out with
compressed air.
1
Put the scrub deck in the raised position and turn the key switch OFF.
2
Remove the front outer body fascia panel from the machine (2 screws).
3
Remove the brush motor spring and put the scrub deck in the lowered position and turn the key OFF.
4
Remove the headlight-mounting panel secured with (6) screws. Then pull the panel out and disconnect wiring and remove.
5
See Figure 5. Remove or loosen the carbon brush inspection cover retaining screw (A) and pull off both the pinned covers (B). Using a
flash light inspect one of the motor brushes. If the carbon brush is worn to a length of 3/8 inch (10 mm) or less remove the scrub brush
motor (see scrub brush removal; section below) and replace all the carbon brushes.
SCRUB BRUSH MOTOR REMOVAL
1
Follow steps 1-4 in the carbon brush inspection section.
2
See Figure 5. Loosen the (2) hex HD. Screws (C) and back them out 3 or 4 turns.
3
Turn the (2) screws (D) (CW) to loosen tension on the brush belt. Then remove the belt from the motor pulley.
4
Disconnect the motor wiring at the motor terminals.
5
Remove the (4) (E) screws securing the motor and lift the motor out through the front of the machine.
6
Follow the steps in reverse order to reassemble. Note: When reassembling, position the motor all the way to the front (the holes in the motor
base are slotted).
7
Connect the motor wire #74 to the positive motor terminal and the #70 wire to the negative motor terminal.
8
Readjust the belt tension; follow the instructions in the belt tension adjustment section.
revised 3/00
FIGURE 5