42 - FORM NO. 56043052 / HYDRO-RETRIEVER™ 2052, CR 1300
SOLUTION SYSTEM
FRONT
E
A
B
C
D
E
E
F
G
H
I
J
K
M
L
N
P
O
Q
R
S
SOLUTION TANK REMOVAL
1
Drain the solution tank using the drain hose found behind the left rear access door.
2
Turn the master key switch off and disconnect the battery connector before servicing.
3
Remove the front outer body fascia panel from the machine (2 screws) and also remove the headlight panel assembly (6 screws).
4
See Figure 3. Remove the solution tank drain hose P-clamp (A) (1 screw).
5
Loosen the solution tank feed Hose Clamp (B) and remove the Hose (C) from the tank Elbow (D). Service Tip Note: The feed Hose (C)
is often difficult to the remove from the barbed elbow Fitting (D). It may be necessary to remove the lower left front corner panel (which
retains the bumper roller) weldment from the machine (7 screws). Back probe the end of the hose with a screwdriver and apply a small
amount of a spray lubricant at the elbow/hose fitting and pull firmly to remove.
6
See Figure 4. Remove the cover from the left electrical panel (12 screws). Then remove the top and middle (4) Screws (T) and loosen
the bottom (2). Note: This step is necessary to allow the needed clearance for removing the tank.
7
Remove the warning strobe light from the machine (2 screws) and disconnect its wiring harness.
8
See Figure 3. Remove the (3) hex HD Screws (E) that secure the tank to the frame mounts. Then lift the solution tank straight up and
off the machine.
9
Follow steps in reverse order to reassemble.
revised 3/00
FIGURE 3